OVERVIEW OF WELDING
PROCEDURES
FLUX CORED ARC WELDING (FCAW) AND GMAW PROCEDURES
For each wire feed speed, a corresponding voltage has been preprogrammed into the machine by welding experts. This preprogrammed voltage is the best average voltage for the procedure at the given wire feed speed. If the wire feed speed is changed on the wire feeder, the voltage automatically changes with it.
In some cases, the operator may want to change the preprogrammed voltages; for example, to compensate for cable and fixture voltage drops. The preset volt- ages can be adjusted on the wire feeder’s Voltage dis- play. When a change is made to the voltage at one
PULSE PROCEDURES
In these procedures, the actual voltage greatly depends on the waveform used. The peak currents, background currents, rise times, fall times, and pulse times all affect the actual voltage. The actual voltage for a given wire feed speed is not directly predictable unless the waveform is known. In this case, it is not practical to preset an actual voltage for the procedure. Instead, an arc length adjustment is provided. The machine “knows” what the best arc length is at the given wire feed speed but allows the operator to change it.
The arc length can be adjusted between 0.5 and 1.5 on the wire feeder’s Voltage display. An arc length trim of 1.0 means that no adjustments will be made to the preset arc lengths. An arc length trim greater than 1.0 increases the preset arc lengths. An arc length trim less than 1.0 decreases the preset arc lengths. The arc length adjustment is factored in at all wire feed speed settings. Refer to Table B.6 for summary of arc length trim.
Increasing the arc length by 10 percent at a given wire feed speed also increases all the other arc length set- tings of the procedure by 10 percent. In the GMAW Pulse process, the display shows the Procedure Description, WFS and Arc Length Trim. Arc length trim is programmed to a default at the factory and may be adjusted on the wire feeder. When the trigger is pulled, the WFS, Actual Arc Voltage and Actual Arc Current are displayed.
STICK/TIG
PROCEDURES
Stick welding can be performed with the Power Wave by attaching a remote control kit to the
See Tables B.3 through B.6 for a summary of the information discussed above.
WAVE CONTROL
The wave control settings of all procedures can be changed on the Power Wave GMAW Pulse, GMAW FCAW, Stick Process Selection Overlay. The wave control is a setup parameter that may be adjusted when the welding procedures are set. This feature provides an easy way to change the arc behavior with- out creating a new procedure. The wave control set- ting of a procedure limits the speed at which the cur- rent waveform of that procedure can change. Typically, each procedure is programmed to have average wave control (at the center of the scale).