Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
| TROUBLESHOOTING & REPAIR |
| |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines | |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | ||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | ||
|
|
|
| |
| OUTPUT PROBLEMS |
|
| |
Machine has no output – fans are | 1. Turn power OFF immediately. | 1. | Perform the Auxiliary | |
running – display is on – a “click- | 2. Check for proper input voltage |
| Transformer Test #1 | |
ing” sound is heard coming from |
|
| ||
(per machine nameplate). | 2. | Perform the Main Contactor | ||
the machine. | ||||
|
| Test. | ||
| 3. Make certain the reconnect |
| ||
|
|
| ||
| panel is configured properly for | 3. | Perform the Reconnect | |
| the applied voltage. |
| Switch Test #1. | |
|
| 4. | Perform the Reconnect | |
|
|
| Switch Test #2. | |
|
| 5. | Perform the Input Rectifier | |
|
|
| Test. | |
|
| 6. | Perform the Switch Board | |
|
|
| Test. | |
|
| 7. | Perform the Snubber and | |
|
|
| Bleeder Resistor Test. | |
|
| 8. | The protection board may be | |
|
|
| faulty. Replace. | |
|
| 9. | The input filter capacitors may | |
|
|
| be faulty. Replace. | |
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-