F-6

F-6

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Machine has no output – fans are

1. Turn power OFF immediately.

1.

Perform the Auxiliary

running – display is on – a “click-

2. Check for proper input voltage

 

Transformer Test #1

ing” sound is heard coming from

 

 

(per machine nameplate).

2.

Perform the Main Contactor

the machine.

 

 

Test.

 

3. Make certain the reconnect

 

 

 

 

 

panel is configured properly for

3.

Perform the Reconnect

 

the applied voltage.

 

Switch Test #1.

 

 

4.

Perform the Reconnect

 

 

 

Switch Test #2.

 

 

5.

Perform the Input Rectifier

 

 

 

Test.

 

 

6.

Perform the Switch Board

 

 

 

Test.

 

 

7.

Perform the Snubber and

 

 

 

Bleeder Resistor Test.

 

 

8.

The protection board may be

 

 

 

faulty. Replace.

 

 

9.

The input filter capacitors may

 

 

 

be faulty. Replace.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1- 800-833-9353.

POWER WAVE 450

Page 66
Image 66
Lincoln Electric SVM112-B service manual Perform the Main Contactor