TROUBLESHOOTING & REPAIR

FULL VOLTAGE CALIBRATION(continued)

FIGURE F.55 - TEST AND CALIBRATION OVERLAY

PROCEDURE

 

 

6. With the machine loaded, monitor the refer-

1. The voltage calibration numbers are stored

 

ence voltage only (external voltmeter). It is

 

the only important reading. Adjust the volt-

 

in the display board.

They are program-

 

 

 

age using the Arrow Keys (100 and 101)

 

mable from the front panel using the Test

 

 

 

until the reference voltmeter reads

30.0

 

and Calibration Overlay.

 

 

 

volts. Press the Enter Key.

 

 

2. Change the PC board in question.

 

 

 

6a. If using a synergic 7 wire feeder, press

3. Install the Test and Calibration Overlay

 

enter then adjust to the desired w.f.s Note

 

L9660-255 and power up the machine. See

 

the gun will be electrically “hot” at this

 

Figure F.55.

 

 

 

time.

 

 

4. Press the Voltage Calibration function (32).

 

 

 

 

 

 

The machine should display the following:

 

 

CAUTION

 

 

 

 

 

VOLTAGE WIRE

WHEN LOADING THE MACHINE WITH THE

 

 

 

+ POLARITY (+67A)

 

 

 

 

 

 

CASE PARTS REMOVED, BE CAREFUL NOT

5. Press the Enter Key (133) on the lower right

TO OVERHEAT THE MACHINE.

 

 

7. Repeat the process by pressing the Voltage

 

side of the overlay. The machine should

 

 

Calibration function again. The next volt-

 

display the following:

 

 

 

 

 

 

 

age sensing point (lead) may be selected by

 

 

 

ADJUST TO 30V

 

 

 

 

 

pressing the down Arrow Key (101).

The

 

 

 

CALIBRATION #=XX

 

above procedure must be repeated six

NOTE: Here “XX” indicates a particular cali-

 

times to set the six sensing points (leads) to

 

30.0 volts. The six test points (leads) are

 

 

bration number

for a given voltage

 

 

 

 

the following:

 

 

 

 

sensing point.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Polarity (+67A)

 

 

 

 

 

WARNING

 

 

 

+ Polarity (+67B)

 

 

 

 

 

 

 

 

 

 

- Polarity (+21A)

 

 

 

 

 

 

 

 

 

 

The machine’s output terminals will be electri-

- Polarity (+21B)

+ Polarity

cally “HOT” when the Enter Key is pressed.

- Polarity

 

 

 

 

 

 

8. If the display board is replaced or dis-

 

 

 

turbed, perform the Sensor Calibration

 

 

 

Test.

 

POWER WAVE 450

Page 206
Image 206
Lincoln Electric SVM112-B service manual Full Voltage Calibration, To Overheat the Machine