Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
RECONNECT SWITCH TEST 2 (continued)
FIGURE F.28 - RECONNECT SWITCH
1
1. RECONNECT PANEL
2. RECONNECT SWITCH
3. LEAD CONNECTIONS
3 2
TEST PROCEDURE |
|
|
|
| ||
| WARNING |
| ||||
1. | Remove main input supply power to the |
|
|
| ||
|
|
|
|
| ||
|
|
|
|
| ||
| machine. |
|
|
| Before continuing with the | |
|
|
|
|
| ||
2. | With the 3/8" nut driver, remove the 4 |
|
|
| test procedure, perform the | |
| screws that hold the handle to the |
|
|
| capacitor discharge proce- | |
| machine. |
|
|
| dure to avoid electric shock. | |
|
|
|
|
|
|
|
3.Remove the rubber gasket (cover seal) from the lift bail.
4. | With the 5/16" nut driver, remove the sheet | 7. Visually check that the following leads are |
| metal screws from the case top. | |
| not damaged or exposed. With the | |
|
| |
5. | With the 5/16" nut driver, remove the | volt/ohmmeter, also test the leads for con- |
| screws holding the right and left case | tinuity: |
sides. Remove the case sides by lifting up and out.
6.Perform the Capacitor Discharge Procedure described earlier in this section of the manual.