TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The display cannot be seen clear-

1.

Adjust the viewing angle of the

1.

Perform the LCD Display Test.

ly or cannot be seen at all.

 

display. Follow the instructions

 

 

 

 

provided in the Operation

 

 

 

 

Section of this manual. (Look

 

 

 

 

under the “LCD DISPLAY

 

 

 

 

ADJUSTMENTS” in the “CON-

 

 

 

 

TROLS AND SETTINGS” sub-

 

 

 

 

section of the Operation

 

 

 

 

Section.)

 

 

 

 

 

 

 

Machine does not respond to

1.

Each time an overlay is

1.

Using the test and calibration

keys being pressed, or the

 

changed, make certain that the

 

overlay L9660-255, perform

machine has improper displays.

 

machine is powered-up with

 

the keyboard/LED test. See

 

 

the new overlay in place.

 

overlay.

 

2.

Make certain that the correct

2.

Perform the Serial Loop

 

 

overlay ID number is displayed

 

Wiring Harness Test.

 

 

on power-up. Refer to the

3. Replace the control board and

 

 

Operation Section of this

 

 

 

perform voltage calibration and

 

 

manual for the overlay descrip-

 

 

 

 

current calibration.

 

 

tion.

 

 

 

 

 

 

3. In some cases, some of the

4. Replace the display board and

 

 

perform voltage calibration.

 

 

keys on the overlay may be

 

 

 

 

 

 

 

locked out. Refer to the

5.

Replace the power board.

 

 

Operation Section of this

 

 

 

 

manual for the overlay descrip-

 

 

 

 

tions.

 

 

 

 

 

 

 

CAUTION