TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

Fans run slow or intermittently –

1.

Make certain the reconnect

1.

Perform the Auxiliary

 

 

display is very dim – no weld out-

 

panel and fuse (F1) jumper “A”

 

Transformer Test #1.

 

 

put.

 

is configured properly for the

 

 

 

 

 

 

input voltage being applied.

 

 

 

 

 

 

 

 

 

 

 

Machine has no output – no dis-

1.

Make sure that not more than

1.

The circuit breaker (5 amp)

 

 

play – fans run – circuit breaker (5

 

5 amps of auxiliary power are

 

may be faulty. Test or replace.

 

 

amp) repeatedly trips.

 

being drawn.

2.

Perform the Auxiliary

 

 

 

 

 

 

 

 

2.

Remove the wire feeder control

 

Transformer #1 Secondary

 

 

 

 

cable from the Power Wave. If

 

and Wiring Harness Test.

 

 

 

 

the symptom disappears, the

 

 

 

 

 

 

wire feeder or control cable is

 

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1- 800-833-9353.

POWER WAVE 450

Page 67