| TROUBLESHOOTING & REPAIR |
| |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines | |
|
| detailed in the beginning of this manual. |
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| ||
| (SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
| Fans run slow or intermittently – | 1. | Make certain the reconnect | 1. | Perform the Auxiliary |
|
| display is very dim – no weld out- |
| panel and fuse (F1) jumper “A” |
| Transformer Test #1. |
|
| put. |
| is configured properly for the |
|
|
|
|
|
| input voltage being applied. |
|
|
|
|
|
|
|
|
|
|
| Machine has no output – no dis- | 1. | Make sure that not more than | 1. | The circuit breaker (5 amp) |
|
| play – fans run – circuit breaker (5 |
| 5 amps of auxiliary power are |
| may be faulty. Test or replace. |
|
| amp) repeatedly trips. |
| being drawn. | 2. | Perform the Auxiliary |
|
|
|
|
|
| ||
|
| 2. | Remove the wire feeder control |
| Transformer #1 Secondary |
|
|
|
| cable from the Power Wave. If |
| and Wiring Harness Test. |
|
|
|
| the symptom disappears, the |
|
|
|
|
|
| wire feeder or control cable is |
|
|
|
|
|
| faulty. |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-