TROUBLESHOOTING & REPAIR
CURRENT CALIBRATION (continued)
FIGURE F.58 – TEST AND CALIBRATION OVERLAY
Return to Section TOC
Return to Master TOC
PROCEDURE
1.Install the Test and Calibration Overlay and apply power to the machine. See Figure F.58.
2.Press the Manual Procedure Entry Key (64). The machine should display the following:
PROCESS 1 SETUP
3.Toggle the Arrow Keys (100 and 101) until the display reads:
PROCESS 1 SETUP
4.Activate the external trigger device.
WARNING
The machine’s output terminals will be electri- cally “HOT” when the trigger circuit is activated.
5.Adjust the potentiometer until the reference (external ammeter) reads 304 amps +/- 1.0 amps. The load voltage should be greater than 15 volts but less than 35 volts.
6.Remove power to the machine.
7.If necessary
8.Replace the machine case parts.