to Section TOC

to Master TOC

E-6

E-6

THEORY OF OPERATION

FIGURE E.6 – OUTPUT RECTIFIER AND CHOKE

 

INPUT

MAIN

OUTPUT

 

 

RECTIFIER

 

 

TRAMSFORMER

RECTIFIER

 

INPUT

AND

POSITIVE

CONTACTOR

RECONNECT

 

CHOKE

 

 

LEFT

 

 

THREE

 

SWITCH

 

 

 

BOARD

 

 

PHASE

 

 

 

 

 

 

 

Return

Return to Section TOC

Return

Return to Master TOC

INPUT

 

FET

POWER

 

ASSEMBLY

INPUT

AUX.

CT

TRANS

 

LINE

 

SWITCH

 

RIGHT

 

 

 

 

SWITCH

PROTECTION

FAN

BOARD

BOARD

 

FET

 

 

 

 

ASSEMBLY

 

POWER

 

 

BOARD

 

CONTROL

BOARD

WATER

COOLERDISPLAY

BOARD

PC

INTERFACE

NEGATIVE

SHUNT

SNUBBER AND

SENSE LEADS

LCD

DISPLAY

KEYPAD

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

OVERLAY

WF1 WF2

OUTPUT RECTIFIER AND CHOKE

The Output Rectifier receives the AC output from the Main Transformer secondary and rectifies it to a DC level with a 40 kHz ripple.

Since the Output Choke is in series with the positive leg of the Output Rectifier and also in series with the welding load, a filtered DC output is applied to the machine output terminals.

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

POWER WAVE 450

Page 54
Image 54
Lincoln Electric SVM112-B service manual Figure E.6 Output Rectifier and Choke