TROUBLESHOOTING & REPAIR
QUICK VOLTAGE CALIBRATION (continued)
FIGURE F.54 - TEST AND CALIBRATION OVERLAY
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
PROCEDURE
1.Before changing or disturbing the display board, power up the machine with the
2.Press the Voltage Calibration function (32). The machine should display the following:
VOLTAGE WIRE
+POLARITY (+67A)
3.Press the Enter Key (133) on the lower right side of the overlay. The machine should display the following:
ADJUST TO 30V
CALIBRATION #=XX
NOTE: Here “XX” indicates a particular cali- bration number for a given voltage sensing point.
WARNING
The machine’s output terminals will be electri- cally “HOT” when the Enter Key is pressed.
4.Record the number displayed for the +67 wire and press the Enter Key (133) again.
5.Repeat the process by pressing the Voltage Calibration function again. The next sens- ing lead may be selected by pressing the down Arrow Key (101). The above proce- dure must be repeated six times to obtain and record the calibration number for six different voltage sensing points. These points are the following:
+Polarity (+67A)
+Polarity (+67B)
-Polarity (+21A)
-Polarity (+21B)
+Polarity
-Polarity
6.Install the “new” replacement display board.
7.With the
ADJUST TO 30V
CALIBRATION #=XX
The calibration number is changed using the up/down Arrow Keys (100, 101). Press the Enter Key when the desired number is dis- played.
8.Repeat the process for all six sensing points (leads).
9.Perform the Sensor Calibration Test.