TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

WELDING PROBLEMS

 

 

 

For no apparent reason the weld

1.

Check for proper wire feed

1.

If zero arc voltage is displayed

 

characteristics have changed.

 

speed setting. In the

 

while welding, the voltage

 

 

 

MIG/MAG and FCAW Modes,

 

sense leads may be broken.

 

 

 

check for proper voltage set-

 

Check the following molex

 

 

 

tings. In the MIG/MAG Pulse

 

plugs and associated wiring for

 

 

 

Modes, check the arc length

 

loose or faulty connections:

 

 

 

trim setting. These controls

 

J60, J62 on the snubber board

 

 

 

are on the wire feeder. In the

 

 

 

 

 

J20 on the control board

 

 

 

Stick Mode, check for proper

 

 

 

 

 

 

 

 

 

preset current setting.

2.

Perform the Welding

 

 

2. Check for proper shielding gas

 

Feedback Test.

 

 

 

 

 

 

 

and gas flow.

3.

The control board may be

 

 

3. Check for loose or faulty weld-

 

faulty. Replace and perform

 

 

 

voltage calibration and current

 

 

 

ing cables.

 

 

 

 

 

calibration.

 

 

 

 

 

 

 

 

 

 

 

 

The arc is “too hot,” and cannot

1.

Perform the full voltage cali-

1.

Check plugs J60, J62 and J20

 

be adjusted.

 

bration.

 

for loose or faulty connections.

 

 

 

 

 

See Wiring Diagram.

 

 

 

 

2. The snubber board may be

 

 

 

 

 

faulty. Replace and perform

 

 

 

 

 

full voltage calibration.

 

 

 

 

3. The control board may be

 

 

 

 

 

faulty. Replace and perform

 

 

 

 

 

voltage calibration and current

 

 

 

 

 

calibration.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1- 800-833-9353.

POWER WAVE 450