F-10

F-10

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Machine has no welding output –

1.

Make sure that the machine

1.

Perform the Wire Feeder

fans run – display is on.

 

was powered up with a proper-

 

Trigger Circuit Test (#1 or #2)

 

 

ly installed overlay. Without an

 

for the appropriate wire feeder

 

 

overlay installed in the Power

 

receptacle (amphenol).

 

 

Wave, or an invalid overlay

2.

If a K941-1 Remote Control Kit

 

 

installed, the machine will not

 

 

 

is attached to the Power Wave,

 

 

have welding output.

 

 

 

 

then perform the K941-1

 

 

 

 

 

2.

Check to see if the Limits or

 

Remote Control Kit Trigger

 

 

Setup overlay is installed on

 

Circuit Test.

 

 

the front panel. These two

3.

Perform the Reconnect

 

 

overlays cannot be used for

 

 

 

Switch Test #1.

 

 

welding.

 

 

 

 

 

 

3. Check for proper input voltage

4. Perform the Output Rectifier

 

 

Diodes Test.

 

 

per machine nameplate.

 

 

 

 

 

 

4. Make certain the reconnect

5. Perform the Switch Board

 

 

Test.

 

 

panel is configured properly.

 

 

 

 

 

 

5. Check to see that when the

6. Perform the Snubber and

 

 

Bleeder Resistor Test.

 

 

trigger is pulled on the wire

 

 

 

 

 

 

 

feeder the wire feeder’s voltage

7.

Perform the Static Capacitor

 

 

display changes to indicate arc

 

Balance Test.

 

 

voltage. If this does not hap-

8.

Perform the Dynamic

 

 

pen, the feeder or control

 

 

 

Capacitor Balance Test.

 

 

cable may be faulty.

 

 

 

 

 

 

6. Check wire feeder control

 

 

 

 

cable for loose or faulty con-

 

 

 

 

nections.

 

 

 

7. If the machine is connected for

 

 

 

 

380VAC or higher and has not

 

 

 

 

been used for a long period of

 

 

 

 

time, the capacitors may

 

 

 

 

require “conditioning.” Let the

 

 

 

 

Power Wave run at an idle

 

 

 

 

state for 30 minutes.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1- 800-833-9353.

POWER WAVE 450

Page 70