Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-204

F-204

TROUBLESHOOTING & REPAIR

PRE-POWERUP SWITCH BOARD TEST PROCEDURE

FOR REPLACEMENT OF SWITCH ASSEMBLY G2402-2 (continued)

FIGURE F.80 - PC BOARD RECEPTACLE

P23

2

3

5

6

1.

Unplug P23 and insert jumper plug into PC

5.

Turn ON the arc start switch.

See Arc Start

 

board receptacle. See Figure F.80.

 

 

PW450 with wire Feeder or Figure

F.79.

2.

Turn ON the preset power switch. See

6.

Attach the oscilloscope probes to each of the

 

Figure

F.78.

 

 

following eight test points.

Each

test point

3.

Press

the MANUAL PROCEDURE ENTRY

 

 

should

look like the oscilloscope

picture in

 

 

Figure

F.81.

 

 

 

(64) key on the Calibration & Test overlay and

 

 

 

 

 

 

 

 

 

 

 

 

 

using the arrow keys (100) and (101) change

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

the Power Wave to “Process 1 Setup 1-1”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode.

 

ALL METERS AND OSCILLOSCOPES MUST

 

 

 

4.

Set the Oscilloscope for:

BE ELECTRICALLY ISOLATED (isolation trans-

 

20 V/div.

former).

 

 

 

 

 

20 uS/div.

 

 

 

 

 

 

 

POSITIVE PROBE

NEGATIVE PROBE

#1 P40 pin 14

P40 pin 16

#2 P40 pin 9

P40 pin 11

#3 P40 pin 6

P40 pin 8

#4 P40 pin 1

P40 pin 3

#5 P41 pin 15

P41 pin 16

#6 P41 pin 9

P41 pin 10

#7 P41 pin 7

P41 pin 8

#8 P41 pin 1

P41 pin 2

POWER WAVE 450

Page 264
Image 264
Lincoln Electric SVM112-B service manual See Arc Start