D-4

D-4

 

MAINTENANCE

 

6. Locate the #9 and #12 terminals, identified by the

FIGURE D.3 – RESISTORS WITH LEADS

 

“Discharge” labels, on each of the four Switch

CONNECTED

Boards. See Figure D.2.

7. Using insulated, needle nose-type jumper leads and insulated gloves, connect one jumper lead to one end of the resistor obtained in step 4. Connect the other jumper lead to the other end of the resistor.

8. Carefully connect the needle nose end of one of the jumper leads to terminal #9. See Figure D.3. Connect the needle nose end of the other jumper lead to terminal #12. Terminals #9 and #12 are indicated by the “Discharge” label. Leave resistor connected for 10 seconds. DO NOT TOUCH TER-

MINALS, RESISTORS, OR ANY INTERNAL MACHINE COMPONENT DURING THIS PROCE- DURE!

FIGURE D.2 – DISCHARGE LABEL

Return

Return to Section TOC

Return

Return to Master TOC

D

I

S C H A R G E

D

I

S C H A R G E

D

I

S C H A R G E

D

I

S C H A R G E

D

I

S C H A R G E

9.Check voltage across terminals (9 and 12) with a DC voltmeter. Terminal 9 has positive polarity and terminal 12 has negative polarity. Voltage should be zero. If any voltage remains, repeat this capac- itor discharge procedure.

10.Repeat discharge procedure (steps 7, 8 and 9) for each of the other three Switch Boards.

Return to Section TOC

Return to Master TOC

POWER WAVE 450

Page 46
Image 46
Lincoln Electric SVM112-B service manual H a R G E