![Accessing Screen Chamber](/images/new-backgrounds/34788/3478839x1.webp)
5 | Accessing Screen Chamber |
|
|
5-1 Opening Screen Chamber
1.Allow all material to run out of the cutting chamber and screen chamber.
2.Shut OFF and LOCKOUT all power including the main disconnect switch.
3.Remove discharge chute located below the screen chamber.
2 fasteners holding the screen cradle in position.
Hopper (Located under screen chamber.)
4.Loosen (2) fasteners holding the screen cradle in position. As the fasteners are designed to remain with the screen chamber, it is not necessary to totally remove them from the screen chamber.
5.Guide the screen chamber to it’s resting position.
Screen
Screen chamber in resting position.
BP1620, BP1628 & BP1640 Granulators | Page 20 BP1600 |