5-2 Closing Screen Chamber

WARNING!

DO NOT LET THE SCREEN CHAMBER DROP!! Guide cradle to it’s resting position.

6. Remove the screen(s) and place them upright on their side.

CAUTION!

The knives mounted on the rotor, and the bed knives located at the edges of the cutting chamber, are extremely sharp. Always wear heavy gloves and exercise care when working in the cutting chamber.

5-2 Closing Screen Chamber

1.Ensure all tools, screws, and debris is removed from the inside of the screen chamber.

2.Place the screen back into its original position, ensuring it is fully seated within the cradle, then CAREFULLY raise the chamber to its closed position. Tighten the captive screws.

3.Insert hopper into the two clips located on either side of the unit walls (see photo).

Discharge should be inserted into these clips located on either side of the unit.

4.Before leaving the area, make sure all components are connected properly.

5.Replace access cover and close doors on optional enclosures.

BP1620, BP1628 & BP1640 Granulators

Page 21 BP1600

Page 21
Image 21
Sterling BP1628, BP1640, BP1620 installation manual 5-2Closing Screen Chamber, Page 21 BP1600

FAQ

What precautions should I take when working in the cutting chamber?

Always wear heavy gloves and exercise extreme care due to the sharp knives mounted on the rotor and the bed knives located at the edges of the cutting chamber.

How do I close the screen chamber?

Remove all tools, screws, and debris, place the screen back into its original position, raise the chamber to its closed position, tighten the captive screws, and make sure all components are properly connected before replacing the access cover and closing doors on optional enclosures.

Where can I find more information about the BP1620, BP1628, and BP1640 models?

Additional details can be found on page 21 of the BP1600 manual.