| 10 | Troubleshooting |
| |
|
|
|
|
|
|
|
|
|
|
| Problem | Possible Cause | Solution |
|
|
|
| Verify that the correct |
|
|
| No power. | pushbuttons are being |
|
|
| depressed and that the |
| |
|
|
| main disconnect switch is |
|
|
|
| in the ON position. |
|
|
|
| Try to locate grounds, a |
|
|
|
| locked rotor or other |
|
|
|
| reasons. |
|
|
| Fuses are blown. |
|
|
|
| Replace fuses with the |
| |
|
|
| size and type shown on |
|
|
|
| the wiring diagram |
|
|
|
| (located in the control |
|
| Motor/(optional) fan |
| enclosure). |
|
| Check for motor and fan | If required, reset #1 |
| |
| motor will not start. | overloads. | MOL, #2 MOL. |
|
|
|
| Check the limit switches |
|
|
|
| at the cutting chamber, |
|
|
| If a limit switch is open. | screen chamber, and |
|
|
| hopper cleanout doors. |
| |
|
|
|
| |
|
|
| Ensure proper actuation |
|
|
|
| and replace if required. |
|
|
| If fan is hinged type | Check safety limit switch |
|
|
| to be sure it is making |
| |
|
| design (optional) |
| |
|
| contact. |
| |
|
|
|
| |
|
| If not equipped with fan | Check jumper on |
|
|
| terminals #3 & #5. |
| |
|
|
|
| |
|
| After completing above |
|
|
|
| inspection, machine will | Call Service Department. |
|
|
| still not start. |
|
|
|
| Machine is overloaded | Reduce amount of |
|
|
| feedstock put into |
| |
|
| with feedstock. |
| |
|
| machine per unit of time. |
| |
|
|
|
| |
| Machine stalls/(optional) |
| Clear the jammed |
|
|
| material then visually |
| |
| fan stalls |
|
| |
| Pieces of feedstock | inspect the rotor to |
| |
|
|
| ||
|
| jammed in the rotor. | ensure it is not damaged |
|
|
|
| and that the knife gaps |
|
|
|
| are correct. |
|
| Problem | Possible Cause | Solution |
|
|
|
|
|
BP1620, BP1628 & BP1640 Granulators | Page 39 BP1600 |