| TROUBLESHOOTING | ||
|
|
|
|
| |||
Symptom |
| Possible Cause |
| Corrective Action |
|
| |
|
|
|
| ||||
|
|
|
|
|
| ||
No Heat (continued) |
| 5. Heating system requires service or |
| sound. This sound usually indicates the thermostat |
| ||
|
| thermostat requires replacement. |
| is operating properly. If the thermostat does not |
| ||
|
| (continued) |
| click, try the reset operation listed above. If the |
| ||
|
|
|
| thermostat does not click after being reset contact |
| ||
|
|
|
| your heating and cooling service person or place of | |||
|
|
|
| purchase for a replacement. If the thermostat clicks, | |||
|
|
|
| contact the furnace manufacturer or a service |
| ||
|
|
|
| person to verify the heating is operating correctly. |
| ||
|
|
|
|
| |||
No Cool |
| 1. SYSTEM button not pressed to COOL. |
| Press SYSTEM button to COOL and lower setpoint | |||
|
|
|
| below room temperature. |
|
| |
|
| 2. Loose connection to thermostat or |
| Verify thermostat and system wires are securely |
| ||
|
| system. |
| attached. |
|
| |
|
| 3. Cooling system requires service or |
| Same procedure as diagnostic for No Heat condition | |||
|
| thermostat requires replacement. |
| except set the thermostat to COOL and lower the |
| ||
|
|
|
| setpoint below the room temperature. There may be | |||
|
|
|
| up to a five minute delay before the thermostat clicks | |||
|
|
|
| in Cooling. |
|
| |
|
|
|
|
|
| ||
Heat, Cool or Fan |
| 1. Possible short in wiring. |
| Check each wire connection to verify they are not |
| ||
Runs Constantly |
| 2. Possible short in thermostat. |
| shorted or touching together. No bare wire should |
| ||
|
| 3. Possible short in heat/cool/fan |
| stick out from under terminal screws. Try resetting |
| ||
|
| system. |
| the thermostat as described above. If the condition |
| ||
|
| 4. FAN Switch set to Fan On. |
| persists the manufacturer of your system or service | |||
|
|
|
| person can instruct you on how to test the Heat/Cool | |||
|
|
|
| system for correct operation. If the system operates | |||
|
|
|
| correctly, replace the thermostat. |
|
| |
|
|
|
|
|
| ||
Furnace |
| 1. The location of the thermostat and/or |
| Digital thermostats normally provide precise tem- |
| ||
(Air Conditioner) |
| the size of the Heating System may |
| perature control and may cycle faster than some |
| ||
Cycles Too Fast |
| be influencing the cycle rate. |
| older mechanical models. A faster cycle rate means | |||
or Too Slow (narrow or |
|
|
| the unit turns on and off more frequently but runs for | |||
wide temperature swing) |
|
|
| a shorter time so there is no increase in energy use. | |||
|
|
|
| If you would like to increase the cycle time, choose |
| ||
|
|
|
| SL for slow cycle in the menu, step 4. If an accept- |
| ||
|
|
|
| able cycle rate is not achieved as received or by |
| ||
|
|
|
| choosing slow cycle, contact a local service person | |||
|
|
|
| for additional suggestions. |
|
| |
|
|
|
|
|
| ||
Thermostat Setting & |
| 1. Thermostat thermometer setting |
| The thermometer can be adjusted +/- 4 degrees. |
| ||
Thermostat Thermometer |
| requires adjustment. |
| See Temperature Display Adjustment in the Configu- | |||
Disagree |
|
|
| ration Menu section. |
|
| |
|
|
|
|
|
| ||
Blank Display and/or |
| 1. Voltage spike or static discharge. |
| Use the Reset Operation at top of previous page. |
| ||
Keypad Not Responding |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Heat Setpoint will |
| 1. The desired setpoint conflicts with the |
| Change system mode to COOL. Raise the Cool |
| ||
not Respond to the |
| setpoint of the COOL mode. |
| setpoint. Return to HEAT mode and set desired |
| ||
Temperature Up Key |
|
|
| temperature. |
|
| |
|
|
|
|
|
| ||
Cool Setpoint will |
| 1. The desired setpoint conflicts with the |
| Change system mode to HEAT. Lower the Heat |
| ||
not Respond to the |
| setpoint of the HEAT mode. |
| setpoint. Return to COOL mode and set desired |
| ||
Temperature Down Key |
|
|
| temperature. |
|
| |
|
|
|
|
|
| ||
Forgot Keypad |
|
|
| CAUTION: This resets the thermostat to factory |
| ||
Lockout Code |
|
|
| default settings of the configuration menu. After |
| ||
|
|
|
| performing this reset, the thermostat will require |
| ||
|
|
|
| configuration again. Be sure that you know the |
| ||
|
|
|
| required configuration settings before resetting. |
| ||
|
|
|
| With the thermostat in any mode, press | and | at | |
|
|
|
| the same time to enter the configuration menu at the | |||
|
|
|
| point where the lockout code is to be entered. Press | |||
|
|
|
|
|
|
|
|
11