CONFIGURATION MENU
Press the SYSTEM button until OFF is displayed, then press the and simultaneously
INSTALLER/CONFIGURATION MENU
| Press | Displayed | Press | or |
| ||
Step | Button(s) | (Factory Default) | to select | Comments | |||
|
|
|
|
|
|
| |
1 | System | MS 2 | SS1, HP2, HP1 | Selects Single stage, | |||
|
|
|
|
|
|
| (Single stage or |
|
|
|
|
|
|
| |
2 | System | 7d | 5d, 0d | Selects Programs Per Week | |||
|
|
|
|
|
|
| |
3 | System | PRG 4 | PRG 2 | Selects Programmable Periods (PRG 2 = 2 | |||
|
|
|
|
|
|
| programmable periods; PRG 4 = 4 programmable periods) |
|
|
|
|
|
|
| |
4 | System | 4:00 HOLD | 0:15 to 4:00 | Selects Temporary Program Override Time | |||
|
|
|
|
| (increments of 15 minutes) |
| |
|
|
|
|
|
|
|
|
5 | System | EMR | OFF |
| Selects Energy Management Recovery OFF or ON | ||
|
| (ON) |
|
|
| ||
|
|
|
|
|
|
|
|
6 | System | FA | SL |
| Selects Fast or Slow Cycle Selection | ||
|
|
|
|
|
|
|
|
7 | System | CL | CL |
| Selects Compressor Lockout CL OFF or ON | ||
|
| (OFF) | (ON) |
|
| ||
|
|
|
|
|
|
|
|
8 | System | CDL | CDL |
| Selects Backlight Display | ||
|
| (ON) | (OFF) |
| |||
|
|
|
|
|
|
|
|
9 | System | FA | FA |
| Selects Fast Second Stage ON or OFF | ||
|
| (ON) | (OFF) |
| |||
|
|
|
|
|
|
| |
10 | System | 0 FLTR | Selects filter replacement run time | ||||
|
|
|
|
|
|
| |
11 | System | 0°F | 4 LO to 4 HI | Selects Temperature Display Adjustment 4 LO to 4 HI | |||
|
| (Room Temperature) |
|
|
| ||
|
|
|
|
|
|
|
|
12 | System | °F | °C |
| Selects temperature display F° or °C selection | ||
|
|
|
|
|
|
|
|
13 | System | AU On | OFF |
| Selects AUTO Mode ON or OFF | ||
|
|
|
|
|
|
| |
14 | System | LR | LR 62 to LR89 | Selects Limited HEAT range | |||
|
| (90) |
|
|
| ||
|
|
|
|
|
|
| |
15 | System | LR | LR 46 to LR 82 | Selects Limited COOL range | |||
|
| (45) |
|
|
| ||
|
|
|
|
|
|
|
|
16 | System | CA | CA |
| Feature Not Available | ||
|
| (OFF) | (ON) |
|
| ||
|
|
|
|
|
|
|
|
17 | System |
|
|
| (ON) |
| Selects Keypad Lockout |
|
| (OFF) |
|
|
| ||
|
|
|
|
| |||
18 | System | 0 | 001 to 999 | Selects Keypad lockout combination number | |||
|
|
|
|
|
|
| Press System to set code |
19
Run
Returns to the OFF position
programmable, SYSTEM button selection will skip Programmable periods (item 3), programmable hold time (item 4) and EMR (item 5).
3)Programmable Periods – This control can be configured for 4 or 2 programmable periods. The display indicates “PRG 4” in the display as default. The programmable
periods can be toggled to “PRG 2” by pressing the or keys.
4)Select Temporary Program Override Time – The thermo- stat can hold any temperature you set it to for the amount of time you select on this option. Your choices are 0:15 to 4:00 hours in 15 minute increments.
Example:
1.You have selected 3:00 hours for the Temporary Pro- gram Override time period.
2.With the thermostat set to Heat or Cool, press or to set the temperature to your preference. The thermostat will maintain this temperature setting for 3 hours with “HOLD” blinking to remind you it is in Temporary Hold. After 3 hours, the thermostat will go back to the program temperature and “HOLD” will no longer blink or display.
6