Perlick DC90ACLT Installation and Tapping ArctiCold Draft Dispenser, Priming the Beer System

Models: DC90ACLT

1 12
Download 12 pages 55.48 Kb
Page 4
Image 4
Installation and Tapping ArctiCold Draft Dispenser

Installation and Tapping ArctiCold Draft Dispenser

Tapping a Single Valve Keg (Sankey)

Be sure beer faucet is in closed position.

Align keg lugs with lug openings on bottom of coupler.

Turn clockwise 14 turn. Pull handle out and down. Keg is now tapped.

Open shut-off valve on CO2 distributor located inside of the cabinet.

Important: Be sure to close this valve when untapping keg.

CAUTION: Do not use keg coupler as a handle to lift keg.

Priming the Beer System

Plug in top refrigeration deck, (15-amp plug), and allow condensing unit to cycle at least once, (circulation pump will run continuously), before tapping the keg.

Couple beer keg to system. Beer temperature in keg should not exceed 42°F.

Apply 14-17 PSIG carbon dioxide gas.

Open faucet and pour for approximately 15 seconds.

Close faucet and wait for at least 15 minutes to allow beer system to “pack”.

You are now ready to tap beer.

Step 1

Single Valve Keg Coupler

Step 3

Step 2

1/4 Tapping a Single Valve Keg (Sankey)

TURN

OUT

DOWN

 

 

 

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

 

 

 

 

 

 

 