Adjustment
1.04.09 Needle position crosswise to sewing direction (on the PFAFF 591)
Requirement
As seen crosswise to the sewing direction, the needle must penetrate in the centre of the needle hole.
4
1
4
2
 4
 4 
| 3 | 
2
Fig. 1 - 09
●Adjust feed wheel post 1 (screws 2, 3 and 4) according to the requirement.