Image 2
Ordering Data

Philips MasterColor® Elite Ceramic Metal Halide 3000K Tubular Single-Ended T6 Lamps

Ordering Data

 

 

 

 

ANSI

Approx.

Approx.

 

Product

 

Pkg.

Nom.

Ballast

Initial

Mean

 

Number

Ordering Code

Qty.

Watt.

Code

Lumens1

Lumens2

CRI

40483-0

CDM Elite35/T6/930

12

39

C130/E

3500

3150

90

14836-1

CDM Elite70/T6/930

12

70

C139/E

7300

6500

90

CDM Elite/T6

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for MasterColor® Ceramic Metal Halide Lamps:Single-Ended CDM-T G12 and CDM-TC G8.5 (Universal);except CDM EliteTC/35/930 and CDM Elite T6/35/930 (Vertical Position ± 60˚); Double-Ended

CDM-TD RX7 (Horizontal ± 45º, Enclosed Fixtures Only)

R“WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer

envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp complies with FDA

Electrical and Technical Data

Lamp Operating Volt. (rms)(Nom.)3 –––––––85 (39W)

–––––––––––––––––––––––––––––––––––86 (70W) Initial Lamp Volt. Range (rms)4 ––––––––––––––80-100 Lamp Operating

Current (Amps) Nominal (rms) ––––––––0.53 (39W)

––––––––––––––––––––––––––––––––––0.98 (70W) Lamp Current Crest Factor (Maximum)–––––––––1.8

Warm-up to 80% Full Brightness –––––––––2 minutes Restrike Time for Hot Lamps–––––––––– 4-8 minutes Ballast Open CircuitVoltage ––––209 RMS Min. (39W)

––––––––––––––––––––––––––198 RMS Min. (70W) Pulse Peak Volts ––––––––––––––––––––––3000-4000 Pulse Width @ 90% Peak –––––2 Micro Sec. Minimum Pulse Repetition Rate (Minimum)5 –––2 per Half Cycle Minimum Operating Temp.––––––––––– -30˚C (-22˚F)

Representative Spectral Power

Distribution of MasterColor® 3000K Lamps

 

100

 

 

 

 

 

 

Energy

80

 

 

 

 

 

 

60

 

 

 

 

 

 

Relative

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

0

450

500

550

600

650

700

 

400

Physical Characteristics

Bulb Size –––––––––––––––––––––––––––––––––T-6 Bulb Finish ––––––––––––––––––––––––––––––Clear

Base ––––––––––––––––––––––––––––––G-12 Bi-Pin Max. Overall Length (MOL) –––––––––––––––––31516" Light Center Length (LCL) ––––––––––––––––––2732'' Arc Length –––––––––––––––––0.17" (4.3mm)(39W)

–––––––––––––––––––––––––0.23'' (5.75mm)(70W) Max. Bulb Temp. –––––––––––––––––– 500˚C (932˚F) Max. Base Temp.–––––––––––––––––––250˚C (482˚F) Arc Tube Material –––––––––Poly Crystalline Alumina Max Bulb to Base Eccentricity –––––––––––––––––3˚

Max.Arc Tube to Base Eccentricity ––––––––––––––3˚

Operating Characteristics

Rated Average Life, Hours.6 ––––––––––––––––12,000

Correlated Color Temp. (CCT)2 ––––––––––––3000K

CIE Chromaticity Approx.2 –––––x-.432 y-.396 (39W)

–––––––––––––––––––––––––––x-.434 y-.395 (70W)

–––––––––––––––––––––––––––––––––––––––––––

Efficacy (lpw)–––––––––––––––––––––––––90 (39W)

––––––––––––––––––––––––––––––––––104 (70W)

Operating Position

Vertical position ± 60˚ (39W); Universal (70W) Enclosed luminaires only.

NOTE: Use on thermally protected electronic ballast only.

Above specifications subject to change without notice.

radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck. WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL

INJURY, PROPERTY DAMAGE, BURNS AND FIRE. Certain lamps that will retain all the glass particles should inner arc-tube rupture occur are commercially available from Philips Lighting Company.

RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

This lamp contains an arc tube with a filling gas containing less than 10 nCi of Kr-85 and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey, 08875.

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED:

LAMP OPERATING INSTRUCTIONS:

1. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.

Allowing lamps to operate until they fail is not advised and may

increase the possibility of inner arc tube rupture.

2. Use only in fully enclosed fixtures capable of withstanding particles

of glass having temperatures up to 1000ºC. Lens/diffuser material

must be heat resistant. Consult fixture manufacturer regarding the

Wavelength — nanometers

1)Measured at 100 hrs. life. Approximate lumen values listed are for vertical operation of the lamp.

2)Approximate lumen output at 40% of lamp rated average life.

3)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.

4)Measured with the lamp operating at rated watts.

5)Option-Pulse Width @ 90% Peak, 1 micro second minimum with 2 pulses per half cycle.

6)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.

Footnotes from front page:

*Based on a MasterColor Elite 3000K Tubular Single-Ended T6 70 W lamp with 7,300 initial lumens vs. a CDM T6 70W lamp with 6,600 initial lumens.

**Based on a MasterColor Elite 3000K Tubular Single-Ended T6 70 W lamp with 6,500 design lumens vs. a CDM T6 70W lamp with 4,950 design lumens.

suitability of the fixture for this lamp.

3. Do not operate a fixture with a missing or broken lens/diffuser.

4. Operate lamp only within specified limits of operating position.

5. Before lamp installation/replacement, shut power off and allow

lamp and fixture to cool to avoid electrical shock and potential

burn hazards.

6. Use only auxiliary equipment meeting Philips and/or ANSI standards.

Use within voltage limits recommended by ballast manufacturer.

A. Operate lamp only within specified limits of operation.

B. For total supply load refer to ballast manufacturers electrical data.

C. Operate CDM-T6 (G12 base) lamps only on thermally

protected ballasts.

D. Operate CDM-TC lamps (G8.5 base), CDM-T6 Elite

lamps, and CDM-T6 39W/842 lamps only on thermally

protected electronic ballasts.

7. Periodically inspect the outer envelope. Replace any lamps that

show scratches, cracks or damage.

8. If a lamp bulb support is used, be sure to insulate the support

electrically to avoid possible decomposition of the bulb glass.

9. Protect lamp base, socket and wiring against moisture, corrosive

atmospheres and excessive heat.

10. Time should be allowed for lamps to stabilize in color when

turned on for the first time.This may require several hours of

operation, with more than one start. Lamp color is also subject to

change under conditions of excess vibration or shock and color

appearance may vary between individual lamps.

11. Lamps may require 4 to 8 minutes to re-light if there is a

power interruption.

12. Take care in handling and disposing of lamps. If an arc tube is

broken, avoid skin contact with any of the contents or fragments.

© 2007 Philips Lighting Company. All rights reserved. Printed in USA 1/08

P-5900-A

www. philips.com

Philips Lighting Company

Philips Lighting

200 Franklin Square Drive

281 Hillmount Road

P.O. Box 6800

Markham, Ontario

Somerset, NJ 08875-6800

Canada L6C 2S3

1-800-555-0050

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification. Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.

Page 2
Image 2
Philips 3000K dimensions Ordering Data, Electrical and Technical Data, Physical Characteristics, Operating Characteristics