Philips Semiconductors Product specification
TOPFET high side switch BUK214-50Y
SMD version of BUK209-50Y
OVERLOAD PROTECTION CHARACTERISTICS
5.5 V VBG 35 V, limits are at -40˚C Tmb 150˚C and typicals at Tmb = 25 ˚C unless otherwise stated.
Refer to TRUTH TABLE.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Overload protection VBL = VBG
IL(lim) Load current limiting VBG 9 V 20 30 40 A
Short circuit load protection
VBL(TO) Battery load threshold voltage1VBG = 16 V 8 10 12 V
VBG = 35 V 15 20 25 V
td sc Response time2VBL > VBL(TO) - 180 250 µs
Overtemperature protection
Tj(TO) Threshold junction 150 170 190 ˚C
temperature3
Tj(TO) Hysteresis - 10 - ˚C
SWITCHING CHARACTERISTICS
Tmb = 25 ˚C, VBG = 13 V, for resistive load RL = 13 .
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
During turn-on from input going high
td on Delay time to 10% VL-4570µs
dV/dton Rate of rise of load voltage 30% to 70% VL- 0.4 1.0 V/µs
t on Total switching time to 90% VL- 110 180 µs
During turn-off from input going low
td off Delay time to 90% VL-5080µs
dV/dtoff Rate of fall of load voltage 70% to 30% VL- 0.7 1.1 V/µs
t off Total switching time to 10% VL- 75 120 µs
CAPACITANCES
Tmb = 25 ˚C; f = 1 MHz; VIG = 0 V. designed in parameters.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Cig Input capacitance VBG = 13 V - 15 20 pF
Cbl Output capacitance VBL = 13 V - 200 300 pF
Csg Status capacitance VSG = 5 V - 11 15 pF
1 The battery to load threshold voltage for short circuit protection is proportional to the battery supply voltage. A graph showing VBL(TO) versus
VBG will be provided in the product specification. After short circuit protection has operated, the input voltage must be toggled low for the
switch to resume normal operation.
2 Measured from when the input goes high.
3 After cooling below the reset temperature the switch will resume normal operation.
September 2002 6 Rev 2.000