Philips T5 VHO Extreme Temperature lamps featuring ALTO® Lamp Technology

Lamp Ordering, Electrical and Technical Data

 

 

 

 

Color

Nom.

Rated Avg. Life (Hrs.)1

Approx.

 

 

 

Product

Ordering

 

Pack.

Temp.

Length

3 Hr.

12 Hr.

Initial

Design

 

Lumen

Number

Code

Watts

Qty.

(Kelvin)

(In.)

Start2

Start3

Lumens4

Lumens5

CRI

Maint.

21771-1

F95T5/835/VHO/A/ALTO

95

40

3500

46

25,000

35,000

7200

6900

85

90%

21772-3

F95T5/841/VHO/A/ALTO

95

40

4100

46

25,000

35,000

7200

6900

85

90%

1)Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.

2)Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.

3)Average life under engineering data with lamps turned off and restarted once every 12 operating hours on a programmed start ballast. Lamp life is appreciably longer if lamps are started less frequently.

4)Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a high frequency reference ballast under standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp. The ballast factor is a multiplier applied to the designated lamp lumen output.

5)Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.

This lamp is better for the environment because of its reduced mercury content. All Philips ALTO® lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.

Note:T5 VHO lamps have new miniature flat pin bases which require new GX5 sockets.

Above specifications subject to change without notice.

Performance (Relative Light Output vs.Temperature)

Philips T5VHO Extreme Temperature Lamps vs. Standard F54T5 Lamps

Relative Light Output (%)

105

100

95

90

85

80

75

70

65

60

0˚C

10˚C

20˚C

30˚C

40˚C

50˚C

60˚C

70˚C

80˚C

32˚F

50˚F

68˚F

86˚F

104˚F

122˚F

140˚F

158˚F

176˚F

Ambient Temperature ˚C

90% Lumen Maintenance

Philips T5 VHO Extreme Temperature Lamps

 

100%

 

98%

 

96%

(%)

94%

 

OutputLight

92%

 

 

90%

 

88%

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Rated Average Life1

Philips T5 VHO Extreme Temperature Lamps

Programmed Start Ballast

BASED ON 3 HOURS PER START2

25,000

BASED ON 12 HOURS PER START3

35,000

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Rated Average Life in Hours

Lamp Operating Hours

Footnotes from front page:

* 90% lumen maintenance at 17,500 hours for the T5 VHO lamp compared to 65% lumen maintenance at 8000 hours for the MH400/U lamp.

‡ 458 system watts (MH400/U) – 418 system watts (T5 VHO) = 40 system watts.

35,000 rated average life (T5 VHO at 12 hours per start) compared to 20,000 rated average life (MH400/U at 13 hours per start)

**For example, with 7200 initial lumens, you only need (4) 95W T5 VHO lamps instead of (6) T5 54W HO lamps when replacing a standard 400W HID System.** For example, with 7500 initial lumens, you only need (4) 95WT5VHO lamps instead of (6)T5 54W HO lamps when replacing a standard 400W HID System.

Page 2
Image 2
Philips HO manual Lamp Ordering, Electrical and Technical Data, 90% Lumen Maintenance, Rated Average Life1