Louver IC Series
Page 2 of 2
Model No. ICS2G9LS26U120SO
LER = FP - 53.4 IW - 57.2 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $4.49
Report Number: G00027
Catalog Number: ICS2G9LS26U120S0
Lamp: (2) F32 T8
Luminaire: IC 2' X 2' Troffer with 3X3 Spectular Louver
Ballast:
Report is based on 2750 Lumens per lamp. Efficiency: 66.2%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.2 | |||
Shielding Angles: |
|
| 23 |
|
| 23 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 21.720 |
| 21.720 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.20 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 73 | 71 | 69 | 67 | 65 | 63 | 64 | 63 | 61 |
2 | 68 | 63 | 59 | 60 | 57 | 54 | 57 | 55 | 53 |
3 | 62 | 56 | 51 | 53 | 49 | 46 | 51 | 48 | 46 |
4 | 57 | 50 | 45 | 48 | 43 | 40 | 46 | 43 | 40 |
5 | 53 | 45 | 40 | 43 | 38 | 35 | 42 | 38 | 35 |
6 | 49 | 41 | 35 | 39 | 34 | 31 | 38 | 34 | 31 |
7 | 45 | 37 | 31 | 35 | 31 | 27 | 35 | 30 | 27 |
8 | 42 | 34 | 28 | 32 | 28 | 25 | 32 | 27 | 24 |
9 | 40 | 31 | 26 | 30 | 25 | 22 | 29 | 25 | 22 |
10 | 37 | 29 | 24 | 28 | 23 | 20 | 27 | 23 | 20 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 4686. | 4497. | 5416. |
55 | 4147. | 4557. | 5917. |
65 | 1779. | 2378. | 2502. |
75 | 312. | 353. | 367. |
85 | 161. | 202. | 161. |
2' x 2' Recessed Fluorescent, 3" 9 or 16 Cell Parabolic Louver Static,
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1552 | 1552 | 1552 |
|
5 | 1545 | 1546 | 1556 | 147 |
15 | 1465 | 1501 | 1530 | 423 |
25 | 1341 | 1353 | 1369 | 625 |
35 | 1165 | 1132 | 1146 | 716 |
45 | 943 | 905 | 1090 | 743 |
55 | 677 | 744 | 966 | 683 |
65 | 214 | 286 | 301 | 271 |
75 | 23 | 26 | 27 | 30 |
85 | 4 | 5 | 4 | 5 |
90 | 0 | 0 | 0 |
|
|
|
|
|
|
TYPICAL V.C.P.'s
|
| Mounting Height |
|
| ||||
| Lengthwise | Crosswise | ||||||
|
|
| ||||||
Room | Luminaires | Luminaires | ||||||
Size | 0 Deg Plane | 90 Deg Plane | ||||||
| 8.5 | 10 | 13 | 16 | 8.5 | 10 | 13 | 16 |
30x30 | 75 | 69 | 60 | 57 | 72 | 66 | 57 | 53 |
40x40 | 80 | 74 | 67 | 60 | 77 | 71 | 64 | 57 |
60x30 | 79 | 74 | 67 | 61 | 76 | 71 | 64 | 58 |
60x60 | 82 | 78 | 72 | 65 | 80 | 75 | 70 | 63 |
100x100 | 85 | 82 | 78 | 72 | 84 | 80 | 76 | 70 |
|
|
|
| |||||
ZONAL LUMEN SUMMARY |
|
|
| |||||
|
|
|
|
| ||||
ZONE | LUMENS | % LAMP |
| % FIXT | ||||
| 1195 |
|
| 21.7 |
| 32.8 | ||
| 1911 |
|
| 34.7 |
| 52.5 | ||
| 3336 |
|
| 60.7 |
| 91.6 | ||
| 3643 |
|
| 66.2 |
| 100.0 | ||
| 0000 |
|
| 0.0 |
| 000.0 | ||
| 3643 |
|
| 66.2 |
| 100.0 |
Ordering Information
Explanation of Catalog Number. Example: ICS2G9LS26UUNVHI
S
2
S
2
6U
-
IC Series: | Body Style: | Fixture | Ceiling Type: | Number of |
Recessed | S=Static | Width | G= Grid | Cells: |
Parabolic |
|
| 9=3 rows | |
|
| |||
suitable for |
|
| T= Slot grid | of 3 |
Thermal |
|
|
| 16=4 rows |
Insulation |
|
|
| of 4 |
Contact |
|
|
|
|
|
|
|
|
|
IC | Standard IC Parabolic |
|
|
|
|
|
| ||
IY | For NYC Code – I.B.E.W. Manufactured |
| ||
|
|
| ||
IX | For NYC Code – Local 3 Manufactured |
| ||
5½" Deep Body |
|
|
|
|
|
|
|
|
|
Louver Finish: | Single "V" | Lamp |
| |||
L = Low iridescence | Reflector | Quantity |
| |||
|
| 2=2 lamps |
| |||
(standard) |
|
|
|
|
| |
P =Low iridescence |
|
|
|
|
| |
Specular |
|
|
|
|
| |
|
|
| Lamp Type/ | |||
W =White Baked |
|
|
| |||
|
|
| Fixture Length: | |||
Enamel |
|
|
| |||
|
|
| 6"U T8 | |||
|
|
|
|
| ||
|
|
|
|
| 2 Lamp Only | |
|
|
|
|
| (Nominal 24") |
|
|
|
| Options: |
|
|
|
| Lamps |
Voltage: |
|
| ||
|
| Flex | ||
120, 277 or |
|
| EM Pack | |
|
| Fuse | ||
| Ballast | Type: |
| (Consult your |
<20THD <10THD representative) | ||||
SO * | H | * | ||
LOL T8 Dimming | PS |
| I– |
*Instant Start Standard
Other dimming options, consult factory.
NOTE:I
For T8 UNV, you must use H Ballast Code.
Options/Accessories
Plaster Frame: Catalog Number: PF24.
Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast; SUFFIX: B.
Fusing: Internal
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X4. (Request Folio
Chicago Plenum: SUFFIX: C.
Specifications
Specifications (continued)
Finish: Chassis
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws.
See: www.lamprecycle.org
Performance: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To prevent glare the VCP shall be not less than 63 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2502 candelas per square meter. To control veiling reflections, luminaire output in the
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2008 a Philips Group | SECTION 7/Folio |
Lightolier is a Philips group brand