Philips Semiconductors Product data sheet
SCC2691Universal asynchronous receiver/transmitter (UART)
2006 Aug 04 5
ABSOLUTE MAXIMUM RATINGS1
SYMBOL PARAMETER RATING UNIT
TAOperating ambient temperature range2Note 4 °C
TSTG Storage temperature range –65 to +150 °C
VCC Voltage from VCC to GND3–0.5 to + 7.0 V
VSVoltage from any pin to ground3–0.5 to VCC +10% V
PDPower Dissipation 300 mW
NOTES:
1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any other condition above those indicated in the operation section of this specification is not
implied.
2. For operating at elevated temperature, the device must be derated based on +150°C maximum junction temperature.
3. This product includes circuitry specifically designed for the protection of its internal devices from damaging effects of excessive static
charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying any voltages larger than the rated maxima.
4. Parameters are valid over specified temperature range. See Ordering Information table for applicable operating temperature and VCC supply
range.
DC ELECTRICAL CHARACTERISTICS1, 2, 3
SYMBOL
PARAMETER
TESTCONDITIONS
LIMITS
UNIT
SYMBOL
PARAMETER
TEST
CONDITIONS
Min Typ Max
UNIT
VIL
VIH
Input low voltage
Input high voltage 0.8 V
All except X1/CLK
X1/CLK 2
0.8VCC VCC
V
V
VOL
VOH4
Output low voltage
Output high voltage
(except open drain outputs)
IOL = 2.4mA
IOH = –400µA2.4
0.4 V
V
IIL Input leakage current VIN = 0 to VCC –10 10 µA
ILL Data bus 3-State leakage current VO = 0.4 to VCC –10 10 µA
IOD Open-drain output leakage current VO = 0.4 to VCC –10 10 µA
IXIL X1/CLK low input current VIN = 0, X2 floated –100 –30 0µA
IXIH X1/CLK high input current VIN = VCC, X2 floated 0 30 100 µA
IX2L X2 low output current VOUT = 0, X1/CLK = VCC –100 µA
IX2H X2 high output current VOUT = VCC, X1/CLK = 0V 100 µA
ICCA
ICCD
Power supply current, active
Power down current5
0°C to +70°C
–40°C to +85°C0.8
1.0 2.0
2.5
500
mA
mA
µA
NOTES:
1. Parameters are valid over specified temperature range. See Ordering Information table for applicable operating temperature and VCC supply
range.
2. All voltage measurements are referenced to ground (GND). For testing, all input signals swing between 0V and 3.0V with a transition time of
20ns max. For X1/CLK, this swing is between 0.4V and 4.0V. All time measurements are referenced at input voltages of 0.8V and 2V and
output voltages of 0.8V and 2V as appropriate.
3. Typical values are at +25°C, typical supply voltages, and typical processing parameters.
4. Test condition for outputs: CL = 150pF, except interrupt outputs. Test conditions for interrupt outputs: CL = 50pF, RL = 2.7k to VCC.
5. For power down current levels in the 1µA region see the UART application note.