ATX |
disconnected in case the user does not need any peripheral. Additionally, the cable harness can be made to any length or output connector type provided that the max load does not exceed 6A for GND return. Please look under specifications for the mating connector type.
Removing the
In order to remove the picoPSU you must release the power connector latch and then remove the unit. Gently lift the picoPSU out from the ATX connector, by grabbing from the picoPSU PCB, not from components or the wire harness.
Specifications,
Volts (V) 5V 5VSB 3.3V
Power Ratings
Max Load (A) | Peak Load (A) | Regulation % |
6A | 7A | +/- 1.5% |
1.5A | 2A | +/- 1.5% |
5A | 7A | +/- 1.5% |
0.05A | 0.1A | +/- 5% |
5A | 7A | Switched input |
At max load, forced air ventilation is required. For fanless operation
Efficiency Ratings, 3.3 and 5V rail
CH1=5V | Efficiency (%) | CH2=3.3V | Efficiency (%) |
1A | 86% | 1A | 85% |
3A | 95% | 3A | 94% |
5A | 93% | 5A | 92% |
7A | 85% | 7A | 85% |
Input Requirements: 12V regulated, min=1A, max=10A (load dependent).
Size: 44.5mm(L) * 20mm(W) * 30mm (H) (1U compliant)
Weight: 45gramms, including cable harness, 20 grams without cable harness.
Connectors
Molex
Page 3 |