- 6 -
Suppress beep tones. Indicator C lights while
suppressing.
- Beep On / Off
Keyboard beep.
- Beep Volume: ---
Volume of keyboard beep.
- Roger beep On / Off
Transmit a beep on keying off the transmitter.
- DTMF tones *** ms
Define length of DTMF tones. Adjust value with
number keys.
- ZVEI tones *** ms
Define length of ZVEI tones used for 5-tone
calling. Adjust value with number keys.
Tone burst *** Hz
Define audio frequency used for opening
repeaters.
Callsign generator Submenu!
- Callsign generator On / On (hold TX) / Off
The transceiver may transmit text in Morse. 'Hold
TX' causes the transmitter to remain keyed until
the text is finished.
- After call On / Off
Callsign may be transmitted immediately after 5-
tone sequence.
- Callsign <text>
Define callsign transmitted during normal
transmissions. See Heading 10.
- Callsign generator Speed: ***
Define Morse speed (0-40).
Adjust value with number keys.
- Callsign generator Only TX / TX & LSP
Callsign may be sent to loudspeaker
- Callsign generator After TX: *** sec
Callsign generator is activated *** seconds after
the transmitter is keyed. Adjust value with number
keys.
- Callsign generator Every: *** sec
Callsign generator is activated every *** seconds.
Adjust value with number keys.
User Submenu!
- LCD backlight Off after: *** s
LCD backlight is switched off automatically ***
seconds after last action.
- My number ***
Define user's personal 5-tone code. The
transceiver produces an alarm tone on reception
of this code.
- Reply ***
This code may be transmitted when the personal
code is received.
- Reply Yes / No
Enable/disable replying to personal code.
- Key acceleration Accel.: X
Define acceleration of up and down key. The
longer the key is pressed, the faster frequencies
will be stepped through.
- Keys Repeat / Once
If a key is held pressed, its function may be
automatically repeated.
- Settings Update / Fixed
When 'Update' is selected, all settings are stored
on switching off. 'Fixed' allows settings to be
stored manually using the next menu item. When
switched on, the transceiver employs the
previously stored settings.
- Settings Store
This allows you to store settings.
- Memory Copy now
This allows the contents of the 24C65/64
EEPROM to be copied.
- <Language> Nederlands / English /
Deutsch
Select one of three languages.
- Status Diagnosis
If the error indicator F is visible, the cause of the
problem may be called up by pressing the H
button.
18. Calls
The transceiver allows up to 10 different tone
sequences to be stored. These tone sequences
may be used to selectively call up stations.
Calling: Display:
- Press H (Select Function )
- Press 0 (Call: )
- Select the number/station to be called
- Press #
Defining the codes: Display:
- Press H (Select Function )
- Press 0 (Call: )
- Select the number/station to be called.
- Press H (Name: )
- Enter name, see Heading 10
- Press H to confirm (Nr. )
- Enter the number
- Press H to confirm
The H button is used to confirm entries. Cancel
entry with any other key.