Solderless Terminal Connections
• Do not connect a cord having an exposed core |
wire to the power terminals of this amplifier |
(Power terminal, GND terminal, System remote |
control terminal). Disconnection or breakage of |
the core wire can cause a fire or |
• Since the wire will become loose over time, it |
must be periodically inspected and tightened as |
necessary. |
• Do not solder or bind the ends of the twisted |
wires. |
• Fasten while making sure to not to clamp the |
insulating sheath of the wire. |
1.Pass the battery wire from the engine compartment to the interior of the vehicle.
•After making all other connections to the amplifier, connect the battery wire terminal of the amplifier to the positive (+) terminal of the battery.
Positive (+) | Engine | Interior of | |
compartment | |||
the vehicle | |||
terminal |
| ||
|
|
• Use the supplied hexagonal wrench to tighten and |
loosen the terminal screw of the amplifier. |
Securely fasten the wire with the terminal screw. |
However, since excessively tightening the termi- |
nal screw of the System remote control has the |
risk of damaging the wire, be careful not to tight- |
en excessively by observing the status of the wire |
when tightening. |
Fuse (40 A) ⋅ 2
Insert the
Drill a 13 mm hole into the vehicle body.
Connecting the Power Terminal
•We recommend that you use the special red bat- tery and ground wire
•Recommended wires size (AWG: American Wire Gauge) is as follows. The battery wire and the ground wire must be same size.
•Use a 10 AWG to 20 AWG wire for the system remote control wire.
Battery Wire and Ground Wire SizeWire Length | less than | less than | less than |
| 4.5 m | 7.2 m | 11.4 m |
| (14 ft. 9 in.) | (23 ft. 7 in.) | (37 ft. 5 in.) |
Wire Size | 8 AWG | 6 AWG | 4 AWG |
|
|
|
|
•Fix the wires securely with the terminal screws.
System remote | Terminal screws |
control terminal |
|
| GND terminal |
Power terminal |
|
| Ground wire |
Battery wire
System remote control wire
WARNINGFailure to securely fasten the battery wire to the terminal using the terminal screws could cause the terminal area to overheat and could result in damage and injury including minor burns.
8