76.DEGITAL SIGNAL LEVEL SELECT(only HDCP model)

Function

External control apparatus sets up the digital signal level of a plasma monitor. Transmission Data

DFH 80H 60H 8FH 01H DATA00 CKS

DATA00 01H : LOW 02H : HIGH

ACK

7FH 60H 80H 8FH 01H DATA00 CKS DATA00 01H : LOW

02H : HIGH

77.MULTI(SPRIT) SCREEN Select

Function

External control apparatus selects a screen mode from alternatives mentioned below, such as single mode, side-by-side, picture in picture, etc., of Plasma Monitor.

Transmission Data

DFH 80H

60H

07H 01H DATA00 CKS

 

DATA00:

00H:

Single Screen

 

01H:

Side by Side 1 (Same Size Screen)

 

02H:

Side-by-Side 2R (Left Screen smaller)

 

03H:

Picture in Picture 1 (sub screen Bottom Left) with size1

 

04H:

Picture in Picture2(sub screen Bottom Right) with size1

 

05H:

Side-by-Side 2L (Left Screen Bigger)

 

06H:

Picture in Picture 1(sub screen Bottom Left) with size2

 

07H:

Picture in Picture 2(sub screen Bottom Right) with size2

 

08H:

Picture in Picture 1(sub screen Bottom Left) with size3

 

09H:

Picture in Picture 2(sub screen Bottom Right) with size3

 

0AH:

Picture in Picture 1(sub screen Bottom Left) with size4

 

0BH:

Picture in Picture 2(sub screen Bottom Right) with size4

 

41H:

Picture in Picture 3(sub screen Top Right) with size1

 

42H:

Picture in Picture 3(sub screen Top Right) with size2

 

43H:

Picture in Picture 3(sub screen Top Right) with size3

 

 

70