76.DEGITAL SIGNAL LEVEL SELECT(only HDCP model)
Function
External control apparatus sets up the digital signal level of a plasma monitor. Transmission Data
DFH 80H 60H 8FH 01H DATA00 CKS
DATA00 01H : LOW 02H : HIGH
ACK
7FH 60H 80H 8FH 01H DATA00 CKS DATA00 01H : LOW
02H : HIGH
77.MULTI(SPRIT) SCREEN Select
Function
External control apparatus selects a screen mode from alternatives mentioned below, such as single mode,
Transmission Data
DFH 80H | 60H | 07H 01H DATA00 CKS |
|
DATA00: | 00H: | Single Screen | |
| 01H: | Side by Side 1 (Same Size Screen) | |
| 02H: | ||
| 03H: | Picture in Picture 1 (sub screen Bottom Left) with size1 | |
| 04H: | Picture in Picture2(sub screen Bottom Right) with size1 | |
| 05H: | ||
| 06H: | Picture in Picture 1(sub screen Bottom Left) with size2 | |
| 07H: | Picture in Picture 2(sub screen Bottom Right) with size2 | |
| 08H: | Picture in Picture 1(sub screen Bottom Left) with size3 | |
| 09H: | Picture in Picture 2(sub screen Bottom Right) with size3 | |
| 0AH: | Picture in Picture 1(sub screen Bottom Left) with size4 | |
| 0BH: | Picture in Picture 2(sub screen Bottom Right) with size4 | |
| 41H: | Picture in Picture 3(sub screen Top Right) with size1 | |
| 42H: | Picture in Picture 3(sub screen Top Right) with size2 | |
| 43H: | Picture in Picture 3(sub screen Top Right) with size3 | |
|
| 70 |
|