7 Bytes integer <CR> (=YYMMDDWWHHMMSS<CR>) Explanation : The real time clock may be set using the following format:
YYthe last two digits of year
MMmonth
DD date
WWday, 00 means Monday, 06 means Sunday HH hour
MMminute SS second
NOTE: Input the
Execution : |
|
| |
| Command String | Status Return | |
|
|
|
|
| WW<CR> | R<CR> | Set Real Time Clock setting mode |
| 98040102083025<CR> | R<CR> | Sets Wednesday, April First, |
|
|
| 8:30:25 AM , 1998 |
6.20Advanced Feature Menu Set
Function | : | The current setting of Industrial Player Menu is rewritten |
Format | : | Integer MS |
Explanation | : | The command rewrites the setting of Industrial Player Menu as like |
follows. Basically, the setting is expressed with some integer value. The value is made up with the sum of each argument you want. The default is 0 when the player was shipped. The player returns an error code if the command is issued when the player is showing Industrial Player Menu on the screen.
The current setting is gotten with the Advanced Feature Menu Request command (?S).
Argument | Function | Description | |
|
| 0 | 1 |
1 | WEEKLY TIMER | OFF | ON |
2 | POWER ON START | OFF | ON |
4 | TITLE PLAY MODE | SINGLE | ALL |
8 | REPEAT MODE | (0) OFF, (8) CHAPTER | |
16 |
| (16) TITLE, (24) DISC *1) | |
32 | BAUD RATE | 4800bps | 9600bps |
64 | TRAY LOCK | OFF | ON |
128 | BLACKBOARD LOCK | OFF | ON |
- 60 -