Immunity Characteristics
•EN55024:1998+A1:2001
•IEC 61000-4-2:2001 Electrostatic Discharge Immunity Test
•IEC 61000-4-3:2002 Radiated Radio-Frequency Electromagnetic Field Immunity Test
•IEC 61000-4-4:1995+A1:2000+A2: 2001 Electrical Fast Transient/Burst Immunity Test
•IEC 61000-4-5:2001 Surge Immunity Test
•IEC 61000-4-6:2001 Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
•IEC 61000-4-8:2001 Power Frequency Magnetic Field Immunity Test
•IEC 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests
Safety
•UL/CSA 60950-1
Environmental Specifications
Temperature | |
• Operating: | -10 to 55 °C |
•Operating
| Survival: | -25 to 65 °C |
• | Storage: | -30 to 75 °C |
Humidity | |
• | Operating: | 5 to 90% RH, 40 °C, non-condensing |
• | Non-operating: | 5 to 93% RH, non-condensing |
Altitude | |
• | Operating: | 10,000 ft (IEC 60068 PT2-13, 4 hours) |
• | Non-operating: | 15,000 ft (IEC 60068 PT2-13, 4 hours) |
Vibration
•Operating (random): 10 to 500 Hz, 3.0 G rms acceleration, 3 hours per axis
Shock
•Operating/Non-operating: 50 G, 11 ms duration, ½ sine, 3 shocks per axis (IEC 60068 PT2-27)