Immunity Characteristics

EN55024:1998+A1:2001

IEC 61000-4-2:2001 Electrostatic Discharge Immunity Test

IEC 61000-4-3:2002 Radiated Radio-Frequency Electromagnetic Field Immunity Test

IEC 61000-4-4:1995+A1:2000+A2: 2001 Electrical Fast Transient/Burst Immunity Test

IEC 61000-4-5:2001 Surge Immunity Test

IEC 61000-4-6:2001 Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields

IEC 61000-4-8:2001 Power Frequency Magnetic Field Immunity Test

IEC 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

Safety

UL/CSA 60950-1

Environmental Specifications

Temperature

 

Operating:

-10 to 55 °C

Operating

 

Survival:

-25 to 65 °C

Storage:

-30 to 75 °C

Humidity

 

Operating:

5 to 90% RH, 40 °C, non-condensing

Non-operating:

5 to 93% RH, non-condensing

Altitude

 

Operating:

10,000 ft (IEC 60068 PT2-13, 4 hours)

Non-operating:

15,000 ft (IEC 60068 PT2-13, 4 hours)

Vibration

Operating (random): 10 to 500 Hz, 3.0 G rms acceleration, 3 hours per axis

Shock

Operating/Non-operating: 50 G, 11 ms duration, ½ sine, 3 shocks per axis (IEC 60068 PT2-27)

LX1200TR User’s Manual (020-0512-00A)

Page 18 of 20