5
Alternate Mounting Solutions
Detaching Network Display from Its Stand
Unscrew screws n the swivel base support column and
pull downo the hinge to release.
Interface for Arm/ Wall Mount Applications
Before installing to mounting device, please refer to Fig.1-3.
The rear of this LCD display has four integrated 4 mm, 0.7 pitch
threaded nuts, as well as four 5 mm access holes in the plastic covering
as illustrated in Figure 1-4. These specifications meet the VESA Flat
Panel Monitor Physical Mounting Interface Standard (paragraphs 2.1
and 2.1.3, version 1, dated 13 November 1997).
Note: M4mm x 11mm (L) screws should be used for a 3mm thick
mounting plate application. Thicker plates should use
appropriately longer screws. The screw threads should extend
between 8 and 10 mm beyond the display surface of the mounting
plate. Follow the mounting device manufacturer’s
reccomendations.
Figure 1-4
Connecting the Display to Your Network

1. Make sure the AC Power Cord is disconnected

2. Connect one end of the Ethernet cable to the Network Display’s

Ethernet (ENET) port. (See Fig 1-5)

3. Verify that the other end of the Ethernet cable is connected to

your LAN/WAN network.

4. Make sure connections are secure and that the Ethernet

connectors have clicked into place.
Figure1-5