ISDN/PSTN Clock Source

Each RTM ISDN card has its own primary and secondary clock source. The first span to synchronize becomes the primary clock source and the second span to synchronize becomes the secondary clock source. This clock is used to synchronize ISDN spans only (it is not the system clock).

A single clock source triggers an alarm that can be turned off by setting the appropriate flag in the system configuration.

Cables Connected to the RTM IP & ISDN Cards

All external connectors are located on the rear panel.

LAN 2

 

Connection E1/T1

 

Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Off/On

 

 

 

 

 

 

 

switch

Cable

Figure 1-4RMX 2000 Rear Panel View with Cables

Do not remove the protective caps from LAN1, LAN3 and ShMG ports.