E:AUDIO TESTS (ITU standards only)
Tests
Test 1: Frequency response (-3dB)
(Insert a
Siren™ 14, 24kbit /s | Siren™ 14, 48kbit /s |
14kHz | 14kHz |
Test 2: Headroom (measured on a Siren™ 14, 48kbit/s connection)
(Insert increasing amplitude 1kHz tone at local site, monitor for overload distortion at remote site)
Overload occurs at: | +10dBm |
Test 3: Audio Level
(Insert
Remote site signal measures: -18dBm measured on audio output
Test 4: Echo Cancellation
Setup The echo canceller is fully automatic in operation.
| Lecture Theatre | Room |
Audio levels adequate? (Y/N) | Not tested | Yes |
Audio quality acceptable? (Y/N) | Not tested | Yes |
Echo cancellation acceptable? (Y/N) | Not tested | Yes |
Quality of double talk | Not tested | Very Good |
Subjectively the quality of the Siren™ 14 audio and echo cancellation was excellent. The provision of: audio level meters for the microphone and VCR inputs; level adjustment on the VCR inputs and an internal tone generator, are all very useful operational features.