HAZARD

RISK OF BURSTING

Air Tank: The air tank on your Air Compressor is designed and may be UM coded (for units with air tanks greater than 6 inch diameter) according to ASME Section VIII, Div. 1 rules. All pressure vessels should be inspected once every two years. To find your state pressure vessels inspector, look under the Division of Labor and Industries in the government section of a phone book .

The following conditions could lead to a weakening of the air tank, and result in a violent air tank explosion:

WHAT CAN HAPPEN

 

HOW TO PREVENT IT

• Failure to properly drain condensed

Drain air tank daily or after each

water from air tank, causing rust

 

use. If air tank develops a leak,

and thinning of the steel air tank.

 

replace it immediately with a new air

 

 

tank or replace the entire compres-

 

 

sor.

• Modifications or attempted repairs

Never drill into, weld, or make any

to the air tank.

 

modifications to the air tank or its

 

 

attachments. Never attempt to

 

 

repair a damaged or leaking air

 

 

tank. Replace with a new air tank.

 

 

 

• Unauthorized modifications to the

The air tank is designed to with-

safety valve or any other compo-

 

stand specific operating pressures.

nents which control air tank pres-

 

Never make adjustments or parts

sure.

 

substitutions to alter the factory set

 

 

operating pressures.

Attachments & accessories:

 

 

Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires, and other inflata- bles can cause them to explode or fly apart, and could result in serious injury.

Follow the equipment manufactur- ers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use compressor to inflate small low pressure objects such as children’s toys, footballs, basket- balls, etc.

HAZARD

RISK OF ELECTRICAL SHOCK

WHAT CAN HAPPEN

HOW TO PREVENT IT

• Your air compressor is powered by

• Never operate the compressor

electricity. Like any other electrically

outdoors when it is raining or in wet

powered device, If it is not used

conditions.

properly it may cause electric

• Never operate compressor with

shock.

protective covers removed or

 

damaged.