RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
Length of Cord in Feet
| 115V | 25 Ft. | 50 Ft. | 100 Ft. | 150 Ft. | 200 Ft. | 250 Ft. | 300 Ft. | 400 Ft. | 500 Ft. | |
| 230V | 50 Ft. | 100 Ft. | 200 Ft. | 300 Ft. | 400 Ft. | 500 Ft. | 600 Ft. | 800 Ft. | 1000 Ft. | |
|
|
|
|
|
|
|
|
|
|
| |
| 18 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | ||
Rating | 18 | 18 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | ||
|
|
|
|
|
|
|
|
|
| ||
18 | 18 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | |||
18 | 18 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | |||
Ampere | 18 | 16 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | ||
|
|
|
|
|
|
|
|
|
| ||
18 | 16 | 12 | 10 | 10 | 8 | 6 | 6 | 6 | |||
18 | 14 | 12 | 10 | 8 | 8 | 6 | 6 | 4 | |||
Nameplate | |||||||||||
16 | 14 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | |||
|
|
|
|
|
|
|
|
|
| ||
16 | 12 | 10 | 8 | 6 | 6 | 6 | 4 | 2 | |||
16 | 12 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | |||
| 14 | 12 | 8 | 8 | 6 | 4 | 4 | 2 | 2 | ||
|
|
|
|
|
|
|
|
|
|
| |
| 14 | 12 | 8 | 6 | 6 | 4 | 4 | 2 | 2 |
OPERATING INSTRUCTIONS
FOREWORD
These
SELECTING THE BIT
These routers accommodate bits with 1/2" diameter shanks that are installed directly into the power unit collet. Collets are available that will allow the use of bits having 1/4" or 3/8" diameter shanks.
CAUTION: Do not use router bits with a diameter in excess of 21/2" in this machine.
CAUTION: While preparing the router for use, while making adjustments and when router is not in use, ALWAYS disconnect it from the power source.
INSTALLING AND REMOVING THE BIT
1.CAUTION: DISCONNECT MACHINE FROM POWER SOURCE.
2.Remove motor unit from base unit as follows:
(a)Loosen clamp screw (A) Fig. 1.
(b)While holding base, turn motor unit COUNTERCLOCKWISE until lower pin (B) in motor housing is disengaged from groove in base.
(c)Lift motor unit free from base unit.
B
A
Fig. 1
5