902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 5

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

CAUTION: Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix W-A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use.

Nameplate Ampere Rating

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

Length of Cord in Feet

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

18

18

18

16

16

14

14

12

12

0-2

 

 

 

 

 

 

 

 

 

 

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

 

 

 

 

 

 

 

 

 

 

4-5

18

18

14

12

12

10

10

8

8

 

 

 

 

 

 

 

 

 

 

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

 

 

 

 

 

 

 

 

 

 

8-10

18

14

12

10

8

8

6

6

4

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

 

 

 

 

 

 

 

 

 

 

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

FUNCTIONAL DESCRIPTION

FOREWORD

Porter-Cable screwdrivers are designed to install or remove various sizes and types of fasteners. The maximum size of which are listed below:

Model 6641 and 6642:

#12 Wood Screws – 1/4" Self-Drilling-Tapping Screws

Models 6640 and 6645:

Commercially available Drywall Screws

ASSEMBLY and OPERATION

TO START AND STOP SCREWDRIVER

CAUTION: MAKE SURE SWITCH IS OFF BEFORE CONNECTING TOOL TO POWER SOURCE.

5

Page 5
Image 5
Porter-Cable 902387, 6641 Functional Description, Motor, Extension Cord Selection, Foreword, To Start and Stop Screwdriver