Porter-Cable CF6131 Storage, To Replace Regulator, Unplug unit, Reapply pipe sealant to gauges

Models: CF6131

1 64
Download 64 pages 31.52 Kb
Page 14
Image 14
Regulator
Manifold
Quick Connect

To Replace Regulator

1.Release all air pressure from air tank. See To Drain Tank in the Maintenance

section.

 

Gauges

Safety

2. Unplug unit.

Valve

 

3.Using an adjustable wrench remove the gauges, quick connect, and safe- ty valve from the regulator manifold.

4. Remove the hose by removing the

hose clamp. NOTE: The hose clamp is not reusable. You must purchase a

new hose clamp, see Replacement

Parts in the Service section or purchase a standard hose clamp at a local hardware store.

5.Remove pump mounting screws securing pump (one on each side).

 

 

Pump Mounting Screw

Hose

Clamp

 

 

 

 

 

Regulator

Manifold

6.

Carefully

slide pump

from

 

 

 

 

 

 

 

brackets and out of the way.

 

 

 

 

 

Pump shown

7.

Using an

adjustable

wrench

 

moved out of

 

 

remove the regulator manifold.

 

the way

 

8.Apply pipe sealant to new regula- tor manifold and assemble, tight- en with wrench.

9. Reapply pipe sealant to gauges,

Regulator

quick connect, and safety valve.

Manifold

 

10.Reassemble all components in

reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary.

2.Drain water from air tank. See To Drain Tank under Maintenance.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

3.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle.

4.Store the air compressor in a clean and dry location.