TROUBLESHOOTING
Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, com- pressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
PROBLEM | CAUSE |
| CORRECTION | |||
|
|
|
|
|
|
|
Excessive tank pressure | Pressure switch does |
| Move On/Off lever to | |||
- safety valve pops off. | not shut off motor when |
| the "Off" position, if | |||
| compressor reaches |
| the outfit does not shut | |||
|
| off contact a Trained | ||||
|
|
| Service Technician. | |||
| Pressure switch "cut- |
| Contact a Trained | |||
| out" too high. |
| Service Technician. | |||
|
|
|
|
|
|
|
Air leaks at fittings. | Tube fittings are not |
| Tighten fittings where air | |||
| tight enough. |
| can be heard escaping. | |||
|
|
| Check fittings with | |||
|
|
| soapy water solution. | |||
|
|
| Do Not Overtighten. | |||
|
|
|
|
|
|
|
Air leaks in air tank | Defective air tank. |
| Air tank must be | |||
or at air tank welds. |
|
| replaced. Do not | |||
|
|
| repair the leak. | |||
|
|
|
|
|
| Risk |
|
|
|
|
|
| |
|
|
| bursting. Do not drill | |||
|
|
| into, weld or otherwise | |||
|
|
| modify air tank or it will | |||
|
|
| weaken. The tank can | |||
|
|
| rupture or explode. | |||
|
|
|
|
|
|
|
Air leaks between | Leaking seal. |
| Contact a Trained | |||
head and valve plate. |
|
| Service Technician. | |||
|
|
|
|
|
|
|
Air leak from | Possible defect in |
| Operate safety valve | |||
safety valve. | safety valve. |
| manually by pulling on | |||
|
|
| ring. If valve still leaks, | |||
|
|
| it should be replaced. | |||
Knocking Noise. | Possible defect in |
| Operate safety valve | |||
| safety valve. |
| manually by pulling on | |||
|
|
| ring. If valve still leaks, | |||
|
|
| it should be replaced. |
16 - ENG