TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, com- pressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

PROBLEM

CAUSE

 

CORRECTION

 

 

 

 

 

 

 

Excessive tank pressure

Pressure switch does

 

Move On/Off lever to

- safety valve pops off.

not shut off motor when

 

the "Off" position, if

 

compressor reaches

 

the outfit does not shut

 

"cut-out" pressure.

 

off contact a Trained

 

 

 

Service Technician.

 

Pressure switch "cut-

 

Contact a Trained

 

out" too high.

 

Service Technician.

 

 

 

 

 

 

 

Air leaks at fittings.

Tube fittings are not

 

Tighten fittings where air

 

tight enough.

 

can be heard escaping.

 

 

 

Check fittings with

 

 

 

soapy water solution.

 

 

 

Do Not Overtighten.

 

 

 

 

 

 

 

Air leaks in air tank

Defective air tank.

 

Air tank must be

or at air tank welds.

 

 

replaced. Do not

 

 

 

repair the leak.

 

 

 

 

 

 

Risk

 

 

 

 

 

 

 

 

 

bursting. Do not drill

 

 

 

into, weld or otherwise

 

 

 

modify air tank or it will

 

 

 

weaken. The tank can

 

 

 

rupture or explode.

 

 

 

 

 

 

 

Air leaks between

Leaking seal.

 

Contact a Trained

head and valve plate.

 

 

Service Technician.

 

 

 

 

 

 

 

Air leak from

Possible defect in

 

Operate safety valve

safety valve.

safety valve.

 

manually by pulling on

 

 

 

ring. If valve still leaks,

 

 

 

it should be replaced.

Knocking Noise.

Possible defect in

 

Operate safety valve

 

safety valve.

 

manually by pulling on

 

 

 

ring. If valve still leaks,

 

 

 

it should be replaced.

16 - ENG

Page 16
Image 16
Porter-Cable CF6131 instruction manual Troubleshooting, Problem Cause Correction