903090 -
MAINTENANCE
CLEAN AND INSPECT DAILY
WARNING: Disconnect tool from air supply before cleaning and inspection. Correct all problems before placing the tool back in use.
Wipe tool clean and inspect for wear or damage. Use
Inspect trigger and safety mechanism to assure system is complete and functional: no loose or missing parts, no binding or sticking parts.
Keep all screws tight. Loose screws can cause personal injury or damage tool.
If tool is used without an
SERVICE AND REPAIRS
All quality tools will eventually require servicing or replacement of parts due to wear from normal use. These operations should ONLY be performed by either an AUTHORIZED
Should you have any questions about your tool, feel free to write us at any time. In any communications, please give all information shown on the nameplate of your tool (model number, type, serial number, etc.).
TROUBLESHOOTING
WARNING: Disconnect tool from air supply before performing any Service Procedure.
SYMPTOM | PROBLEMS | SOLUTIONS |
1.Air leak near top of tool or in trigger area.
Loose screws. | Tighten screws. |
Worn or damaged | Install Overhaul Kit. |
|
2.Tool does nothing or operates sluggishly.
Inadequate air supply. | Verify adequate air supply. |
Inadequate lubrication. | Put 5 or 6 drops of oil into air inlet. |
Worn or damaged | Install Overhaul Kit. |
|
3.Air leak near bottom of tool.
Loose screws. | Tighten screws. |
Worn or damaged | Install Overhaul Kit. |
|
4. | Tool jams frequently. | Incorrect fasteners. | Verify approved fasteners of |
|
|
| correct size. |
|
| Damaged fasteners. | Replace w/undamaged fasteners. |
|
| Magazine or nose | Tighten screws. |
|
| screws loose. |
|
|
| Magazine is dirty. | Clean magazine. |
|
| Driver is worn or damaged. | Install “DRIVER” Maintenance Kit. |
|
|
|
|
5. | Other. |
| Contact a |
|
|
| Service Facility. |
|
| 10 |
|