CONNECTING PROCEDURE FOR RAISING OR SUSPENDING GENERATORS

Failure to properly connect lifting cables, chains, or straps can cause property damage, serious injury or death, and void the

manufacturer's warranty.

Always use cables, chains, or straps rated at 2000 lbs. working load or more to raise or suspend generator.

Never operate generator while suspended. This could cause

property damage, serious injury or death.

1. Route cable, chain, or strap through both lift rings as shown. ALWAYS use both lift rings when raising or suspending generator.

NOTE: Make sure the generator is in a level

Lift Ring

position before raising or suspending to prevent

 

damage.

Lift Ring

15- ENG

D28453

Page 15
Image 15