CAUSE

PROBLEM

CAUSE

CORRECTION

 

 

 

Will not draw

Wand not in low pressure.

See How to Use Wand paragraph

 

in the Operation Section.

chemicals

 

Chemical filter clogged.

Clean filter.

 

 

 

 

 

Chemical screen not in chemical

Insure end of chemical hose is

 

 

fully submerged into chemical.

 

Chemical too thick.

Dilute chemical. Chemical should

 

be the same consistency as

 

 

 

 

water.

 

 

 

 

Pressure hose is too long

Lengthen water supply hose

 

 

instead of pressure hose.

 

Chemical build up in chemical

Have parts cleaned or replaced

 

injector.

by AWSC.

No or low

 

 

Worn seal or packing

Have replaced by AWSC.

pressure (after

 

 

Worn or obstructed valves.

Have replaced by AWSC.

period of

 

 

normal use)

Worn unloader piston.

Have replaced by AWSC.

Water leaking

Worn or broken o-ring.

Check and replace.

at gun/wand

 

 

Loose hose connection.

 

connection

Tighten.

Water leaking

Loose connections.

Tighten.

at pump

 

 

Piston packings worn.

Have replaced by AWSC.

 

 

 

 

 

Worn or broken o-rings.

Have replaced by AWSC.

 

 

 

 

Pump head or tubes damaged

Have replaced by AWSC.

 

from freezing.

 

Oil leaking at

Oil seals worn.

Have replaced by AWSC

pump

 

 

Loose drain plug.

Tighten.

 

 

 

 

 

Worn drain plug, o-ring

Check and replace.

 

 

 

 

Worn fill plug o-ring.

Check and replace.

 

 

 

 

Pump overfilled.

Check for correct amount.

 

 

 

 

Incorrect oil used.

Drain and fill with correct amount

 

 

and type of oil.

 

 

 

 

Vent plug is clogged.

Clean vent plug; blow air through

 

 

it to remove any blockage. If prob-

 

 

lem persists, replace plug.

 

 

 