PROBLEM | CAUSE | CORRECTION | |
|
|
| |
Will not draw | Wand not in low pressure. | See How to Use Wand paragraph | |
| in the Operation Section. | ||
chemicals |
| ||
Chemical filter clogged. | Clean filter. | ||
| |||
|
|
| |
| Chemical screen not in chemical | Insure end of chemical hose is | |
|
| fully submerged into chemical. | |
| Chemical too thick. | Dilute chemical. Chemical should | |
| be the same consistency as | ||
|
| ||
|
| water. | |
|
|
| |
| Pressure hose is too long | Lengthen water supply hose | |
|
| instead of pressure hose. | |
| Chemical build up in chemical | Have parts cleaned or replaced | |
| injector. | by AWSC. | |
No or low |
|
| |
Worn seal or packing | Have replaced by AWSC. | ||
pressure (after |
|
| |
Worn or obstructed valves. | Have replaced by AWSC. | ||
period of | |||
|
| ||
normal use) | Worn unloader piston. | Have replaced by AWSC. | |
Water leaking | Worn or broken | Check and replace. | |
at gun/wand |
|
| |
Loose hose connection. |
| ||
connection | Tighten. | ||
Water leaking | Loose connections. | Tighten. | |
at pump |
|
| |
Piston packings worn. | Have replaced by AWSC. | ||
| |||
|
|
| |
| Worn or broken | Have replaced by AWSC. | |
|
|
| |
| Pump head or tubes damaged | Have replaced by AWSC. | |
| from freezing. |
| |
Oil leaking at | Oil seals worn. | Have replaced by AWSC | |
pump |
|
| |
Loose drain plug. | Tighten. | ||
| |||
|
|
| |
| Worn drain plug, | Check and replace. | |
|
|
| |
| Worn fill plug | Check and replace. | |
|
|
| |
| Pump overfilled. | Check for correct amount. | |
|
|
| |
| Incorrect oil used. | Drain and fill with correct amount | |
|
| and type of oil. | |
|
|
| |
| Vent plug is clogged. | Clean vent plug; blow air through | |
|
| it to remove any blockage. If prob- | |
|
| lem persists, replace plug. | |
|
|
|
17- ENG | D25803 |