POSIFLEX Business Machines PD-7100, PD-7200 user manual Serial Data and Self-test, JP2

Models: PD-7200 PD-7100

1 16
Download 16 pages 50.73 Kb
Page 13
Image 13

 

1 –2 Short

2 –3 Short

 

-Busy status of PD sent

-Busy status of PD sent to host CTS,

JP2

to host as CTS and

handshaking signal of pass through device

 

DSR at the same time

goes to host as DSR directly (default)

Note: There must be the pass through serial output device on the pre- mounted pass through terminator connected to RS232 Out the 9 pin serial pass through port when JP2 is set to 2 –3 Short. Otherwise, the host computer may get a faulty condition in an attempt to write to this serial port.

D. Serial Data and Self-test

Serial characters are received with data formatted as a 10-bit word. The command set is structured to allow transmission of 8 data bits. The data rate is default at 9600 baud per second and can be changed to 19200 baud per second as described above. There is no parity bit and 1 stop bit. The level is RS-232C

start

b0

b1

b2

b3

b4

b5

b6

b7

stop

bit

bit

 

 

 

 

 

 

 

 

Self-test is a very useful feature and can be activated by sending 1F-40 (HEX). The test may be terminated by sending 1B-40 (HEX). The test sequence is as follows

a.Clear screen, Cursor home.

b.Vertical scroll mode test, show product ID and version.

c.For PD-7100/7200, it enters Overwrite mode and displays 20 characters of “A” followed by 20 characters of “B”.

For PD-7110/7210 and PD-7120/7220, it enters Horizontal scroll mode test, and shows 20 CHINESE characters (addresses: B0A1, B1A2, B2A3, ……, BEAF, BFB0, C0B1, ……, C3B4)

d.For PD-7100/7200, it enters Horizontal Scroll mode after clearing screen, then displays ASCII code font of current page from 21 to FF (HEX).

For PD-7110/7210 and PD-7120/7220, it enters Wrap around mode and shows ASCII code font from 21 to 7F (HEX).

e.Go to step a and repeat the test

3 - 6

Page 13
Image 13