CHECK MUFFLER MOUNTING SCREWS

Once each year, ensure muffler mounting screws are secure and tightened properly to prevent damage.

Cap Screws

Muffler Cover

Mounting

Screw Holes

NOTE: The muffler mounting screws are lo- cated behind the cap screws. The cap screws must be removed to access the mounting screws.

SRemove muffler cover.

SLoosen and remove the 2 cap screws from

the muffler mounting screw holes.

STighten the 2 mounting screws (100 in/lbs). S Reinstall and tighten the 2 cap screws (100

in/lbs).

S Reinstall muffler cover.

INSPECT MUFFLER AND SPARK ARRESTING SCREEN

WARNING: The muffler on this prod- uct contains chemicals known to the State of California to cause cancer.

As the unit is used, carbon deposits build up on the muffler and spark arresting screen, and must be removed to avoid creating a fire hazard or affecting engine performance.

TOP VIEW OF MUFFLER

Exhaust

Diverter

Screws

Replace the spark arresting screen every 50 hours of operation or if any damage or breaks in the screen are noted.

NOTE: Do not attempt to clean the spark ar- resting screen.

SRemove muffler cover.

SLoosen and remove both screws from the

exhaust diverter.

SRemove the exhaust diverter and spark ar- resting screen.

SInstall new spark arresting screen.

SReinstall exhaust diverter and both screws.

Tighten screws securely.

SReinstall muffler cover.

NOTE: If any part of the muffler is cracked, broken or damaged, we recommend that the muffler be replaced.

We recommend all service and adjustments not listed in this manual be performed by an authorized service dealer.

CARBURETOR ADJUSTMENTS

Your carburetor is equipped with limiter caps. Adjusting the carburetor is a complicated task. We recommend that you take your unit to an an authorized service dealer. Damage will occur if you turn the needles beyond the limiter stops.

WARNING: Perform the following steps after each use:

S Allow engine to cool, and secure the unit before storing or transporting.

SStore unit and fuel in a well ventilated area

where fuel vapors cannot reach sparks or open flames from water heaters, electric motors or switches, furnaces, etc.

SStore unit with all guards in place. Position unit so that any sharp object cannot acci-

dentally cause injury.

SStore unit and fuel well out of the reach of children.

NEED ASSISTANCE?

Call: 1-800-554-6723.