TRACTOR - - MODEL NO. PXT12538 (96016002200), PRODUCT NO. 960 16 00-22

SCHEMATIC 38

SCH03

 

 

 

BATTERY

 

 

 

 

 

 

SOLENOID

STARTER

 

 

 

 

 

RED

A

RED

RED

 

M

 

 

FUSE

 

 

AMMETER

 

 

 

 

(OPTIONAL)

 

 

 

 

B S

M

 

 

 

 

G

A1

 

WHITE

 

 

L A2

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

CLUTCH / BRAKE

ATTACHMENT CLUTCH

 

 

 

 

(PEDAL UP)

(CLUTCH OFF)

 

 

 

 

 

BLACK

 

 

 

 

BLACK

 

 

 

 

 

 

SEAT SWITCH

 

 

 

 

(NOT OCCUPIED)

 

 

 

BLACK

 

BLACK

 

 

 

 

 

GRAY

 

 

 

 

GRAY

 

REVERSE SWITCH

NOT IN REVERSE

BLACK

SHORTING CONNECTOR

BLACK

 

BLACK/WHITE

IGNITION

SPARK PLUGS

 

 

GAP

 

 

 

UNIT

 

(2 PLUGS

 

 

 

 

ON TWIN CYL. ENGINES)

 

 

BLUE

HOUR

 

BLACK

 

 

 

METER

 

 

 

 

FUEL

(OPTIONAL)

 

 

 

 

 

 

 

 

LINE

 

 

 

BLUE

 

 

CHARGING SYSTEM OUTPUT

28 VOLTS AC MIN. @ 3600 RPM

 

 

 

3 AMP DC @ 3600 RPM

(CHARGING SYSTEM DISCONNECTED)

 

FUEL SHUT-OFF

 

 

 

RED

 

SOLENOID

 

 

 

 

 

LIGHTING SYSTEM OUTPUT

DIODE

STATOR

 

 

5 AMP AC @ 3600 RPM

LIGHT SWITCH

ORANGE

14 VOLTS AC MIN. @ 3600 RPM (LIGHTS OFF)

 

 

 

 

 

 

BROWN

 

 

BLACK

IGNITION SWITCH

POSITION

CIRCUIT

“MAKE”

 

 

 

 

 

 

OFF

M+G+A1

 

RUN/OVERRIDE

B+A1

 

RUN

B+A1

L+A2

START

B + S + A1

 

NOTE

YOUR TRACTOR IS EQUIPPED WITH A SPECIAL ALTERNATOR SYSTEM. THE LIGHTS ARE NOT CONNECTED TO THE BATTERY, BUT HAVE THEIR OWN ELECTRICAL SOURCE. BECAUSE OF THIS, THE BRIGHTNESS OF THE LIGHTS WILL CHANGE WITH ENGINE SPEED. AT IDLE THE LIGHTS WILL DIM. AS THE ENGINE IS SPEEDED UP, THE LIGHTS

WILL BECOME THEIR BRIGHTEST.

3

HEADLIGHTS

NON-REMOVABLE REMOVABLE

CONNECTIONS CONNECTIONS

WIRING INSULATED CLIPS

NOTE: IF WIRING INSULATED CLIPS WERE REMOVED FOR SERVICING OF UNIT, THEY SHOULD BE RE-INSTALLED TO PROPERLY SECURE YOUR WIRING.

Page 3
Image 3
Poulan PXT12538 manual Schematic, Fuse