4. Installation

4.0 Inspection

Inspect the UPS upon receipt. The packaging is recyclable; save it for reuse
or dispose of it properly.

4.1 Placement

Install the UPS in a protected area with adequate air flow and free of
excessive dust. Do not operate the UPS where the temperature and humidity
is outside the specified limits.

4.2 Connect Computer Interface (optional)

UPSMON series software (or other power management software) and an
interface kits can be used with this UPS. Use only kits supplied or approved
by the manufacturer. If used, connect the interface cable to the 9 pin
computer interface port on the back panel of the UPS.
Note: Computer interface connection is optional. The UPS works
properly without a computer interface connection.
Caution: Use only factory supplied or authorized UPS monitoring
cable !

4.3 Connect external battery pack (optional)

Before connecting, make sure the external battery pack and the connector
cable are compatible with this UPS.
Note: External battery connection is not necessary. The UPS works
properly without a external battery pack connection.
Caution: Use only factory supplied or external battery connection
cable !

4.4 Connect the telephone/modem lines (optional)

Connect a single line telephone or a modem line into the telephone/modem
surge protection sockets on the back of the UPS. The RJ-45/RJ-11 modular
sockets accept standard single line telephone connections. This connection
will require another length of telephone cable (supplied).
6