TYPICALTYPICAL INSTINSTALLAALLATIONTION
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Figure 1 | |
|
|
|
|
|
|
|
|
|
|
Key | Description | Key | Description | Key | Description | Key | Description | ||
A | Air hose | D | G | Quick Coupler | J | Female Connector | |||
B | E | Air Hose | H | Male Connector | K | Spray Gun | |||
C | Tee Fitting | F | Whip Hose | I | Air Tool |
|
|
|
|
OPERAOPERATINGTING INSTRUCTIONSINSTRUCTIONS
To begin using the tool:
1.As a standard practice, drain water from the air compressor tank and air lines prior to use each day (reference your compressor operators manual for detailed instructions).
2.Install a 1/4” NPT male connector (not included) into the air inlet port on the tool (see Figure 2). Note: Use Teflon® Tape on all threaded connections.
3.Turn on the air compressor and allow it to build up pressure.
4.Adjust the air compressor’s regulator or the supply line regulator to 90 PSI.
Figure 2
Always make sure the tool is disconnected from any air supply before changing the grinding stones or accessories, or serious injury could occur.
Grinders will attain extremely high R.P.M. or free speed. Use only accessories that are rated with R.P.M. equal to or greater than the
Inspect each grinding stone for cracks or chips prior to mounting. DO NOT use a grinding stone that is chipped, cracked or damaged in any other way.
5. | Select the desired grinding stone or accessory. NOTE: This tool is | Figure 3 |
| equipped with a 1/4” collet chuck, which uses grinding stones and |
|
| accessories with a 1/4” spindle. |
|
To change the grinding stones or accessories:
a.Loosen the collet chuck with the collet wrenches (included with your tool) by placing one collet wrench on the flats of the grinder shaft to hold it from turning. Place the other collet wrench on the flats of the collet chuck
and turn |
|
To loosen |
b.Insert a grinding stone or accessory into the collet chuck, then turn the collet chuck clockwise to tighten using the collet wrenches.
Make sure the grinding stone or accessory spindle is fully inserted into the collet chuck opening and the collet chuck is securely tightened. Loose attachments could fly off during operation and cause serious injury.
c. | After mounting a grinding stone or accessory, hold the |
|
| grinder under a workbench and run it for at least 60 | To Tighten |
seconds to be sure the grinding accessory is secure.
Make sure no one (including the operator) is in the operating plane of the grinding accessory.
To change the collet chuck:
a.Loosen the collet chuck with the collet wrenches (included with your tool) by placing one collet wrench on the flats of the grinder shaft to hold it from turning. Place the other collet wrench on the flats of the collet chuck and turn
4 - ENG