Procom HM-BT-BAT user manual Initial PC Setup/ Bluetooth Modem Discovery, PC Applications

Models: HM-BT-BAT

1 6
Download 6 pages 33.83 Kb
Page 2
Image 2

ProComSol, Ltd

HM-BT-BAT User Manual

 

 

Initial PC Setup/ Bluetooth Modem Discovery

The following procedure must be done at least once for the PC to “Discover” the HM- BT-BAT.

1.Turn on the HM-BT-BAT. It does not need to be connected to the HART network.

2.Run the Bluetooth driver software that came with your PC or Bluetooth adapter (ie Linksys). There is typically a Bluetooth icon on the system tray that can be double clicked.

3.Select “Find Bluetooth Devices” or “Site Survey” to locate any Bluetooth devices in the area. You could also search for services. Search for “Serial Services” to also locate Bluetooth devices.

4.A device labeled “HART Modem” should be discovered.

5.Double click on the “HART Modem” icon. The available serial service will appear as “ZV-SPP”, and say it is not connected.

6.Double click on “ZV-SPP”. The Bluetooth connection will be made and the assigned COM port will be reported. This is typically COM8. Note this port number for your application software.

7.Some Bluetooth drivers may prompt for a “Passcode”. Enter “1234”, without the quotes.

Discovery needs to be repeated only when adding or changing HM-BT-BAT modems, or when multiple modems are in the Bluetooth area.

PC Applications

Start your PC application and set the com port setting to use the com port reported during Discovery. Use the application as normal. The HM-BT-BAT looks like a normal RS232 device to the application software. The application software does not need to be modified.

Multiple HM-BT-BAT Modems

When several modems are in the same area, the Discovery process needs to be repeated. The modems will appear as “HART Modem (1)”, “HART Modem (2)”, etc. It may require trial and error to determine which modem is connected to the desired HART network.