CLEARANCE TO COMBUSTIBLES

CLEARANCE TO COMBUSTIBLES

Back………………2”/50.8mm

Sides……………..6”/156.4mm

Floor……………..0”/0mm

Top……………….24”/610mm

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60Hz circuit with a properly grounded outlet is required. Preferably, the heater will be on a dedicated circuit. Other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is on operation. The unit comes standard with a 6’ (1828mm) long three wire cord exiting from the rear of the fireplace. Plan the installation to avoid the use of an extension cord. If an extended cord must be used, it must be a minimum 16 AWG three wire with grounding type plug connector and rated no less than 1900 Watts.

WARNING: Electrical outlet wiring must comply with local building codes and all other applicable regulations to reduce the risk of fire, electrical shock and injury.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the electrical system if necessary.

ELECTRICAL SPECIFICATIONS

Voltage………………120 VAC/60Hz

Total Amps…………..11.3 Amps

Total Watts…………..1345 Watts

Heater Ratings………1200 Watts

SERVICE INSTRUCTIONS

WARNING: Disconnect power

before attempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury

REPLACING LIGHT BULBS

This fireplace uses two clear 120 Volt, 60 Watt, E-12 socket base light bulbs (small base, chandelier candle type).The 60 Watt bulbs are located under the log set/ember bed. For convenience, if one of the bulbs burns out, it may be a good idea to replace both of the light bulbs.

1.Turn off power to the unit by unplugging the power cord.

2.Let fireplace cool if it has been operating.

3.Open the front door by pulling the handle.

4.Remove the two screws that secure the log set in position.

5.Remove the two screws of the front baffle and take them out.

6.Examine the bulbs to determine which one needs to be replaced.

7.While holding the socket, unscrew the defective bulb(s).

8.Install the new light bulb(s) by holding the socket and screwing them in.

9.Reinstall the bafflelog set and screen. Follow the above procedure in reverse order.

WARNING: Do not exceed 60 Watts per bulb. Use of higher rated bulbs may result in a fire causing property damage and personal injury.