ProForm PFTL591040 user manual Problem One of the upper body arms squeaks during use

Models: PFTL591040

1 34
Download 34 pages 871 b
Page 28
Image 28

PROBLEM: One of the upper body arms squeaks during use

SOLUTION: a. Correcting this problem requires a small amount of white marine grease, available at most hardware stores. Turn the Resistance Knob (83) counterclock- wise until it can be removed. Remove the Resistance Cone (89) and the Upper Body Arm (95), along with the 3/8” Washers (84), Spring Washer (85), Thrust Washers (86), and Thrust Bearing (87). (Note: If the Resistance Sleeve [91] or Resistance Plate [88] comes out of the Resistance Bracket [92] or Resistance Cone, press it back in.) Apply a thin layer of white marine grease to the outer surface of the Resistance Cone (89). Reattach all parts in the order shown at the right.

a

 

92

95

91

 

 

86

89

85

83

 

88

 

87

 

84

PROBLEM: The incline of the treadmill does not change correctly or does not change when iFIT.com CDs and videos are played

SOLUTION: a. With the key inserted in the console, press one of the Incline buttons. While the incline is changing, remove the key. After a few seconds, re-insert the key. The treadmill will automati- cally rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline system.

28

Page 28
Image 28
ProForm PFTL591040 user manual Problem One of the upper body arms squeaks during use